DMX512 R
EFERENCE
G
UIDE
1 2
02.3004.0300.54
Series 300 DMX Power Pack
When power is applied to the DMX Power Pack, the unit detects which luminaire is connected. A four-
position switch on the front panel is used to select the mode.
•
Modes 1-4: operate VL6, VL5, VL5B, VLM and VL5Arc luminaires.
•
Modes 5 and 6: operate VL6B luminaires.
•
Modes 7 and 8: operate VL7/VL7U luminaires.
•
Modes 9 and 10: operate VL7B/VL7UB luminaires.
Figure 1-3: DMX Power Pack (DPP)
Note: The TERM and SW4 switch settings do not effect the DMX512 mode.