PRG Controlling VARI-LITE Equipment Using DMX 512 User Manual
Page 119

T
ESTING
AND
T
ROUBLESHOOTING
: T
EST
S
OFTWARE
0 2. 3 0 0 4. 0 3 00 . 5 4
111
4
1
Spin gobos CW (25%) wheel
does not move
0
Spin gobos CW (100%)
wheel does not move
010
Strobe Test
9
Strobe to EOT stop (65%)
(CLSD)
8
Strobe to middle position
between EOT Stop (66%)
(OPEN)
7
Strobe open to closed stop
repeatedly (25%) (i.e.
cycling)
6
Cycling (35%)
5
Cycling (45%)
4
Cycling (55%)
3
Cycling (65%)
2
Cycling (75%)
1
Cycling (85%)
0
Cycling (Full Speed)
013
All Async
All tests above will run asyn-
chronously. All motors will
reach respective EOT stop (if
applicable) and begin motion
to opposite EOT stops at
each motor’s earliest oppor-
tunity. Motion will not be coor-
dinated between motor.
Flashing display indi-
cates sensor not hit.
Solid display indicates
sensor hit.
021
Sensors
9
Monitor Lens 3 Sensor
8
Monitor Lens 2 Sensor
7
Monitor Lens 1 Sensor
6
Monitor Strobe Sensor
5
Monitor Fixed Gobo Sensor
4
Monitor Rotating Gobo
Wheel, Wheel position Sen-
sor and Gobo Orientation
Sensor
3
Monitor Plate 2 Saturation
Sensor
2
Monitor Plate 2 Color Sensor
1
Monitor Plate 1 Saturation
Sensor
0
Monitor Plate 1 Color Sensor
022/
023
Pan/Tilt Encoders
9
Display current most signifi-
cant digit (Xxxx) of the
reported encoder value.
Repeatedly monitored.
Table 4-9: VL7B/VL7UB Spot Luminaire Mechanical Tests (Continued)
Test Number
Test Parameter
Error Codes/Comments