beautypg.com

Maxim Integrated 6612_OMU_S2_URT_V1_13 User Manual

Page 48

background image

6612_OMU_S2_URT_V1_13 Firmware Description Document

FDD_6612_010

48

Rev. 1.1

CE

Parameter

Location

(hex)

LSB

Default

Comment

Example

SAG

Threshold

11

VMAX A

*4.2551E-

07 (Vpk)

+313350

The voltage

threshold for

SAG warnings.

The default value

is 80 Vpk if

VMAX = 600 V.

)11=+313350

80 Vpk SAG Threshold.

QUANTA

12

VMAX A

* IMAX A

*

1.8541E-

10

(Watt)

0

Compensation

added to the Watt

calculation for

Outlet 1. Used

for compensation

at low current

levels. Keep

below 10000d.

QUANTB

13

VMAX A

* IMAX B

*

1.8541E-

10

(Watt)

0

Compensation

added to the Watt

calculation for

Outlet 2. Used for

compensation at

low current

levels. Keep

below 10000d.

QUANT

VAR A

14

VMAX A

* IMAX A

*

1.8541E-
10 (Watt)

0

Compensation

added to the VAR

calculation for

Outlet 1. Used for

compensation at

low current

levels. Keep

below 10000d.

QUANT

VAR B

15

VMAX A

* IMAX B

*

1.8541E-
10 (Watt)

0

Compensation

added to the VAR

calculation for

Outlet 2. Used for

compensation at

low current

levels. Keep

below 10000d.

QUANT IA

16

(IMAX A)

2

*

4.6351E-11

(A

2

)

0

IA input

compensation

added for input

noise and

truncation in the

squaring

calculation for I

2

.

Used for

compensation at

low current

levels. Keep

below 10000d.