beautypg.com

Maxim Integrated 6612_OMU_S2_URT_V1_13 User Manual

Page 33

background image

FDD_6612_ 010

6612_OMU_S2_URT_V1_13 Firmware Description Document

Rev. 1.1

33

Output

Location

(hex)

LSB

Comment

Example

Irms_wb B

Max

75

mArms

Outlet 2 maximum wideband rms

current measured.

If the largest wideband current

measured on Outlet 2 is 30 Amps

)75?

Returns:

+30.000

VARs_wb B

Min

76

mW

Outlet 2 minimum wideband

reactive power measured (per

second).

If the largest VARs measured on

Outlet 2 is 80 VARs

)76?

Returns:

+80.000

VARs_wb B

Max

77

mW

Outlet 2 maximum wideband

reactive power measured (per

second).

If the largest VARs measured on

Outlet 2 is 300 VARs

)77?

Returns:

+300.000

VAs_wb B

Min

78

mW

Outlet 2 minimum wideband

apparent power measured (per

second).

If the smallest VAs measured on

Outlet 2 is 80 VARs

)78?

Returns:

+80.000

VAs_wb B

Max

79

mW

Outlet 2 maximum wideband

apparent power measured (per

second).

If the largest VAs measured on

Outlet 2 is 300 VARs

)79?

Returns:

+300.000

Power

Factor_wb B

Min

7A

Outlet 2 minimum wideband power

factor measured. Minimum is

defined as the most negative or

least positive number.

If minimum wideband power factor

measured on Outlet 2 is –0.6

)7A? Returns:

-0.600

Power

Factor_wb B

Max

7B

Outlet 2 maximum wideband power

factor measured. Maximum is

defined as the most positive or

least negative number.

If maximum wideband power

factor measured on Outlet 2 is 0.9

)7B? Returns:

+0.900

Phase

Angle_wb B

Min

7C

mDegrees

Outlet 2 minimum wideband phase

angle measured.

If the minimum wideband phase

angle measured on Outlet 2 is

10 degrees

)7C?

Returns:

+10.000

Phase

Angle_wb B

Max

7D

mDegree

Outlet 2 maximum wideband phase

angle measured.

If the maximum wideband phase

angle measured on Outlet 2 is

70 degrees

)7D?

Returns:

+70.000

Reserved

7E

Reserved

Reserved

Reserved

7F

Reserved

Reserved