PXL-250 Tiger Controller
1530 Old Oakland Road, Suite 100
01835-002 Rev. 4.2
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: [email protected]
Page 7 of 25
PXL-250
Quick Start Guide
4.3
Connecting a Keri Systems Proximity Reader to a PXL-250P
•
The "A" reader is wired to TB5.
•
The "B" reader is wired to TB6.
Figure 4: Proximity Reader Connections
4.4
Connecting a Wiegand Compatible Reader to a PXL-250W
The PXL-250W controller can be configured to accept input from single-line LED, dual-line LED, and Essex keypad
Wiegand input devices (through the Doors™ software).
NOTE: The Wiegand Reader must transfer data according to the Security Industry Association's Wiegand Reader
Interface Standard (document number AC-01D-96). Keri Systems, Inc. cannot guarantee the performance or reliability
of Wiegand Readers that do not meet these data transfer guidelines.
NOTE: All Keri Systems proximity readers use 12 VDC power while most Wiegand compatible readers use 5 VDC
power. Check your reader's power requirements and verify jumper JP4 is set correctly per the Verify the Wiegand
Reader Supply Voltage section on page 21. Early revisions of the surface mount PXL-250W mislabeled the JP4 jumper
as JP5. All instructions for the JP4 jumper apply to the jumper labeled as JP5 (see Figure 1 on page 1 for the location
of the jumper).
NOTE: The wire colors called out in Figures 5 and 6 are industry standard wire colors. However, some manufacturers
may not follow these industry standard designations. Before installation, please refer to the Wiegand device’s manual to
see if the device’s wire colors follow the industry standard. If not, then match the wire’s purpose to the callouts in
Figures 5 and 6 before installation.