7 reader responses to access control events, 0 general information on inputs, Pxl-250 tiger controller – Keri Systems PXL-250 Quick Start User Manual
Page 23: Pxl-250 quick start guide
PXL-250 Tiger Controller
1530 Old Oakland Road, Suite 100
01835-002 Rev. 4.2
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: [email protected]
Page 23 of 25
PXL-250
Quick Start Guide
5.7
Reader Responses to Access Control Events
During day-to-day activity, the reader will respond to access control events in a specific manner. Table 3 provides a
summary of the reader's LED and beeper actions during access control events.
6.0
General Information on Inputs
A controller input detects a state change generated by a device outside the controller that may prompt a response from
the controller. Input devices that generate a state change may be normally closed or normally open. This section
provides a brief description of normally closed versus normally open inputs.
Table 3: Reader Responses to Access Control Events
Event
Reader’s LED Status
Reader’s Beeper Status
waiting for an
event
displays a steady Amber LED
silent
access granted
displays a Green LED until the door is closed or
the door unlock time is reached
one long Beep
access denied
flashes a Red LED
one short Beep
door alarm
flashing Red LED for the duration of the alarm condition
pulsating Beep for the duration of the
alarm condition
door RTE
displays a Green LED until the door is opened or the door
unlock time is reached
one long Beep