Quick Start Guide
DO NOT
•
make modem phone line connections through PBX telephone switching systems - most modems are not compatible
with PBX systems leading to disconnection problems with the modem
•
locate the PXL-250 controller near EMI sources - EMI sources can affect the performance of the controller
•
use switching power supplies - they are EMI sources
•
route network and reader cables beside power cables - transients on the power cables may be picked-up by network
and reader cables
•
stretch or over-tension cables
•
route over sharp objects
•
let the wires get tangled
•
mix PXL-250s with PXL-100s in the same network
•
route all controllers in a network in spur, hub, or loop configurations
•
connect earth ground
1
to the network cable shield - the PXL-250 automatically connects earth ground to the shield
at one point on the network to prevent ground loops
•
use gender changer plugs when making RS-232 serial communication connections (unless you know it is a
"straight-through" plug) - gender changers may have internal wiring changes that can disrupt communications