Keri Systems EP2500 User Manual
Ep2500 intelligent controller, General, Setting up the ep2500 hardware
Mercury Security Corporation, Copyright 2011 EP2500
DOC 10107-0030 REV: 1.03
Page 1
Information subject to change without notice.
EP2500 Intelligent Controller
Installation and Specifications:
1. General:
The EP2500 intelligent controller provides decision making, event reporting, and database storage for
the Mercury hardware platform.
It communicates with the host via on-board 10-BaseT/100Base-TX Ethernet port or port 1. Port 1 may
be set up as RS-232, 2-wire RS-485 or an optional 10-BaseT/100Base-TX using a Lantronix Micro100
interface daughter board. Subcontrollers are connected via ports 2 and 3 using 2-wire RS-485.
It is recommended that the EP2500 be mounted .25" above any conductive surface.
2. Setting Up the EP2500 Hardware:
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2)
this device must accept any interference received, includ-
ing interference that may cause undesired operation.
1
4
3
2
S1
VB
AT
1
2
3
4
5
6
LNK
SPD
TB
2
J1
J11
TXD
TR+
RXD
TR-
RTS
CTS
GND
POR
T 1
485
J7
232
J9
J8
J1
0
POR
T 2
PO
R
T 3
TR+
TR-
GND
TR+
TR-
GND
J4
J5
GND
FLT
GND
TMP
VIN
GN
D
ACT
3.3
V
5V
J1
J13
J14
J15
J16
J17
- +
J3
S2
BT1
3V BR/CR2330
U1
U4
U3
U5
U7
J6
J12
www.mercury-security.com
2355 MIRA MAR AVE. LONG BEACH, CA 90815-1755, (562) 986-9105 FAX (562) 986-9205