PXL-250 Tiger Controller

1530 Old Oakland Road, Suite 100

01835-002 Rev. 4.2

San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: [email protected]

Page 2 of 25

Quick Start Guide

PXL-250

1.0

Specifications

Unit Dimensions

PXL-250 controller PCB
- 6.75 inches high by 6.00 inches wide by 1.75 inches deep, including wiring connectors
- (17.15 cm by 15.25 cm by 4.45 cm)

PXL-250 controller PCB with an SB-293 Satellite Board
- 7.25 inches high by 6.00 inches wide by 1.75 inches deep, including wiring connectors
- (18.45 cm by 15.25 cm by 4.45 cm)

PXL-250 controller PCB with an LCD-1 Alpha/Numeric Display
- 7.70 inches high by 6.00 inches wide by 1.75 inches deep, including wiring connectors
- (19.60 cm by 15.25 cm by 4.45 cm)

PXL-250 controller PCB with an SB-293 Satellite Board and an LCD-1 Alpha/Numeric Display
- 8.10 inches high by 6.00 inches wide by 1.75 inches deep, including wiring connectors
- (20.60 cm by 15.25 cm by 4.45 cm)

Enclosure
- 9.70 inches high by 8.20 inches wide by 2.60 inches deep
- (24.65 cm by 20.85 cm by 6.60 cm)

Operating Temperature/Humidity Range

0°F to 140°F (-18°C to 60°C)

0% to 90% Relative Humidity, non-condensing

Controller Power Requirements

12 VDC @ 1 A

Current Draw

maximum current draw 270 mA for a controller plus reader current draw (refer to Table 1 for Reader current draw)

120 mA max for a PXL-250 Controller

150 mA max for an SB-293 Satellite Board

NOTE: If an electronic locking device (such as a magnetic lock, a door strike, or similar device) is to be driven by the
same power supply as the PXL-250 controller, please ensure the power supply provides enough current to drive every
device connected to that supply plus an adequate safety margin. AC power cannot be used.

Controller Memory Retention

5 year lithium battery back up to support controller RAM and real-time clock

Output Relay Contact Rating

1 Amp @ 24 VDC

Table 1: Reader Current Draw

Reader Type

MS-3000

MS-4000

MS-5000

MS-7000

MS-9000

Current Draw

50 mA

50 mA

100 mA

200 mA

200 mA