Pxl-100: smart entry controller, 1) warnings, 2) pxl-100 diagram – Keri Systems PXL-100 User Manual
Page 2
Page 2
01816-100 Rev. E
1530 Old Oakland Rd., Ste 100 San Jose, CA 95112 U.S.A. (800)260-5265 (408)451-2520 Fax (408)441-0309
PXL-100: SMART ENTRY CONTROLLER
.
1) Warnings
This document should only be used for the design 5 board or later versions. To identify a
design 5 board, look for the two relays in the center of the PC board. If there are two next to
each other, it is a design 5 board.
When disconnecting or reconfiguring any PXL-100 or peripheral products, ensure that the
power has been disconnected. Serious damage such as RAM failure may occur if an option
board or other peripheral product is disconnected while power is on.
2) PXL-100 Diagram
GND
NC
GND
REX (RTE)
GND
NC
(Jumper
Selectable)
NO
COMMON
NC
EARTH
GND
+12 VDC
12 VAC
12 VAC
GRN LED
BEEP
+12 VDC
GND
RDR
RED LED
Firmware
Battery
3 V Lithium
#BR2325
External Time Zone
Exit Button or PIR
Magnetic Door Switch
12 VDC
Alarm Device
12 VDC Out
Gnd
Relay
Relay
Relay
To Door Lock or Parking Gate
To B Proximity Reader
Green
Red
Black
Blue
Door Lock
Relay
Alarm Out
Relay
(new for design 5)
GRN LED
BEEP
+12 VDC
GND
RDR
RED LED
To Primary Proximity Reader
Green
Red
Black
Blue
JP6 J4
JP3
3) Features and Functions of the PXL-100 Smart Entry Controller
The PXL-100 can be used as a stand alone unit or function as a networkable access control system
capable of controlling up to sixty-four doors (with the addition of an option board). Standard features
include:
- a database capacity of 7000 unique users per controller
- transaction buffers capable of storing 3000 events per controller
- expansion port for adding special feature option boards
- built in power supply that can run off 12VDC or 12VAC and can power door strikes
or magnetic locks
- RS-232 serial port configurable to communicate with a PC or printer
- an optional RS-485 network communication capable of linking up to 32 controllers
on a single network
- I/O including door status, request to exit, two 10Amp Form-C relay for door strikes
and alarm shunting.