Resetting configuration to factory settings 4-5, Resetting configuration to factory settings – Cyclades AlterPath BladeManager User Manual
Page 87

First Time Configuration Wizard
AlterPath BladeManager Manual
4-5
•
Enter Date (format MM/DD/YYYY)
•
Enter Primary Ethernet IP Address (Static/None).
•
Enter Secondary Ethernet IP Address (Static/None)
•
Configure Ethernet Subinterfaces (Yes/No/List)
•
Configure Ethernet VLANs (Yes/No/List)
•
Enter Ethernet default gateway
•
Enter System’s Hostname (30 characters max)
•
Enter System’s Domain name (60 characters max)
•
Enter Primary nameserver’s IP address
•
Enter the NTP Server
•
Enter email (SMTP) server
•
Enter Authentication Method (local/radius/tacacs+/ldap/kerberos/nis/
active_directory)
Note: Depending on the Authentication Method that you select, the system
will prompt you for additional information. See “Setting the 
Authentication Method” on page 4-8 for more information. 
>> Resetting Configuration to Factory Settings
If you make a mistake during the First Time Configuration (or if you need to 
make a change in the configuration), you can reset the configuration to its 
factory default settings and start over. To reset the configuration, follow these 
steps: 
1. Log in to the management console as root.
2. Type in: defconf and press 
3. Type in: reboot and press 
Example:
BladeManager login: root
Password:
. 
.
[root@BladeManager root]# defconf
WARNING: this will erase all of your current configuration and restore the 
 system's factory default configuration. This action is irreversible!