beautypg.com

Conversion parts required, Power burner gas kettles, Kgl-40 – Cleveland Range HA-MKGL-80 User Manual

Page 42

background image

NOTE: Use thread sealant compatible with propane gas
on all threaded piping connections.

1.

Disconnect electrical connection.

2.

Shut off main gas supply and disconnect kettle from
supply line.

3.

Remove TOP COVER.

4.

Remove PLUG and SPRING.

5.

Remove GAS ORIFICE and “O” RING.

6.

Replace with new GAS ORIFICE and “O” RING.

7.

Replace SPRING and PLUG.

8.

Replace TOP COVER.

9.

Place gas conversion label next to rating label.

10. Reconnect electrical supply.

Power Burner Gas Kettles

BTU's per Gas

Water

# of

Hour

Type

Column

Orifices

KGL-40,
KGL-40-T,

140000

NAT

3.5

1

MKGL-40-T,

140000

LP

3.5

1

KGL-60 to 100,
KGL-60-T to 80-T,
KGL-40-TSH,

190000

NAT

3.5

1

KGL-40-F to 60-F,

190000

LP

3.5

1

KGL-40-SH to 60-SH,
HA-MKGL-60 to 100,
HA-MKGL-60 to 100-T

Conversion Parts Required

KGL-40

Part No.

Description

Quantity

KE95549

Conversion Label

1

KE54420-1

Air Intake Washer

1

KE53403-5

Gas Orifice

1

FA05002-29

“O” Ring

1

KGL-60 to 100

Part No.

Description

Quantity

KE95549

Conversion Label

1

KE54420-1

Air Intake Washer

1

KE53403-7

Gas Orifice

1

FA05002-29

“O” Ring

1

FIELD CONVERSION

INSTRUCTIONS -
Natural Gas to Propane Gas

PLUG

SPRING

GAS ORIFICE

“O” RING

TOP COVER