beautypg.com

IC Realtime Combo Series: 8 Channel DVR with built-in 10 LCD monitor User Manual

Page 29

background image

20

z

Please connect the NC port of the alarm sensor to the 10.2-inch combo DVR alarm

input(ALARM)

z

Use the same ground with that of 10.2-inch combo DVR if you use external power to the

alarm device.

Figure 3-9

3.9.3 Alarm Output Port

z

1-channel relay alarm output (NO contact). Provide external power to external alarm device.

z

To avoid overloading, please read the following relay parameters sheet carefully.

z

RS485 A/B cable is for the A/B cable of the PTZ decoder.

Relay Specification

Model:

JRC-27F

Material of the
touch

Silver

Rated switch capacity

30VDC 2A, 125VAC 1A

Maximum switch power

125VA 160W

Maximum switch voltage

250VAC, 220VDC

Rating

Resistance

Load)

Maximum switch currency

1A

Between touches with same
polarity

1000VAC 1minute

Between touches with different
polarity

1000VAC 1minute

Insulation

Between touch and winding

1000VAC 1minute

Surge voltage

Between touches with same
polarity

1500V (10×160us)

Length of open
time

3ms max

Length of close
time

3ms max

Mechanical

50×106 times (3Hz)

Longevity

Electrical

200×103 times (0.5Hz)

Temperature

-40℃ ~+70℃

3.10 RS232