To store a pair of Dual Watch frequency into the Dual Watch Memories.

1. Press the E/VFO key to select VFO Mode.

2. Press the Band key to select the required band.

3. Adjust the Squelch so the receiver is muted.

4. Enter one of the frequencies that you wish to monitor.

5. Press Func DW. The ‘D’ Dual Watch icon will be displayed.

6. Enter a second frequency using the control knob or the number keys.

7. Press the E/VFO key to accept. The Dual Watch function will begin.

8. Now press Func MW. The receiver enters the Memory Write Mode and selects

the Du (Dual Watch) memory bank.

9. Use the control knob to select an empty channel to store the frequency pair.

10. Press Func MW again to store the two frequencies. They will be stored Axx and

bxx where xx is the empty channel you selected.

To recall a pair of Dual Watch frequencies from the Dual Watch Memories.

1. Press the E/VFO key to select VFO Mode.

2. Set the squelch level to a point where the receiver is just quiet.

3. Press Func MR. The receiver will enter the Memory Read Mode.

4. Press the BANK key repeatedly to step through the memory banks until Du

is selected.

5. Select the required channel using the control knob.

6. Briefly press the SCAN/SRC key. Dual Watch will begin with the receiver

monitoring the channels in the selected Dual Watch memory.