beautypg.com

Ppendix, Arameter, Efault – Flintec FT-12 Manual User Manual

Page 43: Able

background image

FT-12 Technical Manual, Rev. 1.35 November 2010

Page 43 of 44

A

PPENDIX

6: P

ARAMETER

S

D

EFAULT

T

ABLE

Parameter Factory

defaults

0-- Interface

00- Serial Interface 1

0 Data format

2 = Printer

1 Baud rate

3 = 9600

2 Handshake

0 = Disable

3 Address

0

4 Data length and parity

0 = 8 bit, no parity

5 Checksum

1 = Enable

01- Serial Interface 2

10 Data format

0 = Disable

11 Baud rate

3 = 9600

12 Handshake

0 = No

13 Address

0

14 Data length and parity

0 = 8 bit, no parity

15 Checksum

1 = Enable

02- Serial Interface 3

20 Data format

0 = Disable

21 Baud rate

3 = 9600

22 Handshake

0 = Disable

23 Address

0

24 Mode

0 = RS232C

25 Data length and parity

0 = 8 bit, no parity

26 Checksum

1 = Enable

03- Ethernet / Profibus

30 Ethernet data format

0 = Disable

31 Ethernet address

0

04- Printer

40 Print out format

2 = Multi line

41 Date & Time

1 = Will be printed

42 CN (Consecutive number)

1 = Will be printed

43 ID1

0 = Won’t be printed

44 ID2

0 = Won’t be printed

45 Minimum print

20 kg

46 Print control

0 = With Print Key

47 Line feed

11 = 1 LF + 1 LF

48 Form feed

0 = No

49 Quantity of copies

1

1-- Configuration

10- Application

100 Mode

0 = Basic weighing

101 Threshold weight

100 kg

102 Ending rate

50%

103 Period (Dynamic)

9.9 s

104 Alarm

0 = Disable

105 Filling type

0 = Gross

11- Start

Up

111 Auto power off

0 = Disable

112 Store Tare at power off

0 = Disable

113 Auto tare clear

0 = Disable

114 Buzzer active?

0 = Disable

12- Filter

120 Filter

7

13- Digital

I/0

130 Outputs

0 = Disable

131 Input 1

0 = Disable

132 Input 2

0 = Disable

133 Input 3

0 = Disable

14- Entries

140 Date entry

dd.mm.yy

141 Time entry

hh.mm

142 Label no. entry

Parameter Factory

defaults

2-- Scale Parameters

20- Set

up

200Approved

0 = No

201Increased indication

0 = With x10 key

202Power on zero

2 = ± %10

203Zero with key

1 = ± %2

204Auto zero tracking

0 = Disable

205Tare

1 = With Tare Key

206Motion detector

1 = ± 0,5e

207Tilt switch

0 = Disable

208Stability time

0.0 s

21- Scale

Build

210Scale Type

0 = Single Range

211Capacity 1 / d1

212Capacity (2) / d(2)

6 kg / 1 g

3-- Calibration / Adjustment

30- Calibration

300Gravity
301Calibration

31- Adjustment

310Zero adjustment

311Span adjustment

312Span adjustment under load

4-- Analogue Output

40- Signal

Selection

400Analogue Output Signal Type

41- Zero

Adjustment

410Coarse Zero Adjustment

411Fine Zero Adjustment

42- Span

Adjustment

420Coarse Span Adjustment

421Fine Span Adjustment

8-- Metrological Data

80- Legal

Metrology

800Calibration counter
801Alibi memory
802Calling a record
803Print Alibi memory
804Alibi memory information

9-- Diagnostics

90- Tests

900Key Pad test
901Serial interface 1 test
902Digital input test
903Digital output test
904mV indication

91- Serial

numbers

910FT-1x serial no.
911Option 1 serial no. (if installed)
912Option 2 serial no. (if installed)
913Option 3 serial no. (if installed)

97- Calibration

coefficients

97X Calibration coefficients
99- Print

Parameters

990All parameters
991Load default parameters