beautypg.com

] printer, 040 x ] print out format, 045 ] minimum print – Flintec FT-12 Manual User Manual

Page 26: 046 x] print control, 047 xy] line feed, 048 x] form feed, 049 x] quantity of copies

background image

FT-12 Technical Manual, Rev. 1.35 November 2010

Page 26 of 44

[04-] Printer

If one of the serial interfaces is selected as printer, the label settings will be made in this sub-block.

[040 X ] Print Out Format

1 : Single line

2 : Multi line

3 : EPL format

4 : Totalizing

[041 X] Transfer of Date and Time via serial interface

0 : no

1 : yes

[042 X] Transfer of CN (Consecutive no.) via serial interface

0 : no

1 : yes

[043

X] Transfer of ID1 via serial interface

[044

X] Transfer of ID2 via serial interface

0 : no transfer

1 : only transfer of code

2 : only transfer of alphanumerical data

3 : transfer of code and the alphanumeric data

Warning:

The code / alphanumeric data table should be loaded into the ID memory via serial interface to print the

alphanumeric data of the ID.

[045 ] Minimum Print

[XXXXXX]

If the weight is less than the value entered here, the data will not be printed

[046

X] Print Control

0 : Printing with key

1 : Auto print

2 : Print interlock

Explanation:

If set to “Auto print”, the data will automatically be printed when the value is stable and higher than the

minimum print value. The weight value should fall below the minimum print value to reprint. If this parameter is set to
“Print interlock”, after printing the weight must change for reprint.

[047 XY] Line Feed

X = 0, 1, 2…9

Number of empty lines at the top of the label (numerical key entry)

Y = 0, 1, 2…9

Number of empty lines at the bottom of the label (numerical key entry)

[048

X] Form Feed

0 : No FF

1 : After printing the printer will go to the next page automatically

[049

X] Quantity of Copies

X = 0, 1, 2…9

Number of labels to print for each weighing

Note:

This function is only valid for parameter [040] = 2.