Any input to FT-11 is in two double words and according to the table below.
FT-11 Input
D31M
SB
D30 D29 D28 D27 D26 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16
Bit no.
D15 D14 D13 D12
D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1
D0
LSB
W31
MSB
W30 W29 W28 W27 W26
W25
W24
W23 W22
W21
W20 W19 W18
W17 W16
RxPDO 1
(R_DW1)
W15 W14 W13 W12 W11 W10
W9 W8 W7 W6 W5 W4 W3 W2 W01
W00
LSB
0 0 0 0
SP3
SP2
SP1
0
Zero
Tare
CLR
Select
RxPDO 2
(R_DW2)
Not used
Here R_DW1 provides the value received from the PLC and R_DW2 describes the meaning of this value as
indicated below.
Bit Nr.
RxPDO2 (R_DW2)
Description
31...28
Not used
Always 0
27 Setpoint
3
26 Setpoint
2
25 Setpoint
1
A transition from 0 to1 activates the command. The value of the first and second
word is loaded to the corresponding setpoint.
24 Not
used
Always 0
23 Zero
22 Tare
21 Print
20 Clear
A transition from 0 to1 activates the command.
19...16 Select
0000 Gros
weight
0001 Displayed
weight
0010 Net
weight
0011 Tara
weight
0100
Setpoint 1 (not continuous)
0101
Setpoint 2 (not continuous)
0110
Setpoint 3 (not continuous)
0111
Latest alibi record no. (always 32-bit integer)
1000
Latest alibi gross weight
1001
Latest alibi tare weight
1010
Zero calibration + Calibration status (see table above)
1011
Span calibration + Calibration status (see table above);
First write the calibration weight value in R_DW1
1100 Calibration
status
(see table on page 50)
15...0
Not used