EVCO EV9376J9 User Manual
Page 5

Evco S.p.A. • Code 1049376E00 • page 5/8
To memorise another program, repeat the procedure given in this
paragraph.
To exit the procedure:
• press
and
or do not operate for 15 s: the “delay” LED
will switch-off.
To exit the procedure in advance:
• press
and
or do not operate for 15 s during the procedure
(i.e. before confirming the selection of the
program: any modifications will not be saved).
11.5
Exclusion of the cooking phase of a program for
benefit of the successive one
• make sure no procedure is in progress
• press
for 4 s: the instrument passes to the successive cooking
phase.
11.6
Learning the information regarding the program
during the execution of the same
• make sure no procedure is in progress
• press
and
: the display and the LEDs will show the following
information (for example), after which the
instrument will restore the normal display. To pass
from one piece of information to the next press
LED
DISPLAY
-
7 (upper part: program 7) and PrOG (lower part)
-
P71 (upper part: program 7, phase 1) and CorE (lower
part; the cooking phase)
and 1 P71 (upper part: program 7, phase 1) and 150 (lower
part; the value of the work set-point)
and 2 P71 (upper part: program 7, phase 1) and 100 (lower
part; the value of the core set-point)
-
P72 (upper part: program 7, phase 2) and COnt (lower
part; the cooking phase)
P72 (upper part: program 7, phase 2) and 150 (lower
part; the value of the work set-point)
-
End
The display shows every setting for 1 s.
To exit the succession of settings:
• press
and
The instrument displays the information memorised in the program
and not any modifications made during execution of the same.
12
PROGRAMMED SWITCH-ON
12.1
Preliminary considerations
The programmed switch-on allows to plan the automatic switch-on of
the instrument.
On switch-on the instrument will function with the settings memorised
in a program (see chapter 11).
It is possible to plan 14 switch-on times; there are 12 possible
combinations of switch-on days.
If there is a power cut in progress at the switch-on time, the switch-on
will be re-proposed when the power is restored.
12.2
Setting programmed switch-on
To access the procedure:
• make sure that the instrument is in on status and that no procedure
is in progress
• press
and
: the upper part of the display will show flashing
“H01”(it is the label of the first switch-on time),
the lower part will show a label relative to a
combination of switch-on days and the “delay”
LED will flash.
The following combinations of days for switch-on available are the
following:
LABEL
COMBINATION OF DAYS
- - -
no day
- 1 -
Monday
- 2 -
Tuesday
- 3 -
Wednesday
- 4 -
Thursday
- 5 -
Friday
- 6 -
Saturday
- 7 -
Sunday
1 - 5
from Monday to Friday
1 - 6
from Monday to Saturday
1 - 7
from Monday to Sunday
6 - 7
Saturday and Sunday
To select an ignition time:
• press
or
within 15 s (for example to select “H07”).
To select a combination of days to which the selected switch-on time
will be applied (in the example, “H07”):
• press
while the top part of the display is flashing: the lower part
of the display will show a flashing label relative to a
combination of days and the upper part will switch-on
• press
or
within 15 s (for example to select “1 - 5”).
To set the selected switch-on time (in the example “H07”):
• press
while the lower part of the display is flashing: the lower
part of the display will show the switch-on time; the left
part will flash.
The time is displayed in the 24 h format (hours:minutes)
To modify the hour:
• press
or
within 15 s
• press
: the right part of the indication relative to the ignition time
will flash.
To modify the minutes:
• press
or
within 15 s
• press
: the upper part of the display will again show the label of
the flashing switch-on time (in the example “H07”) and
the lower part will show the combination of days again (in
the example “1 - 5”).
To set another programmed switch-on, repeat the procedure given in
this paragraph.
To go back to the previous level:
• press
during the procedure.
To exit the procedure:
• press
and
or do not operate for 15 s: the “delay” LED will
switch-off.
To exit the procedure in advance:
• press
and
or do not operate for 15 s during the procedure
(i.e. before modifying the minutes: any
modifications will not be saved).
For the instrument to switch-on automatically on the day
and time set, these must be in the programmed switch-on
status.
To pass from the on status (or the stand-by status) to the programmed
switch-on status:
• make sure no procedure is in progress
• press
and
1 s:
If the instrument is in the programmed switch-on status:
• the upper part of the display will show the program label which will
be started on programmed switch-on of the instrument (if the start-
up of any program is not envisioned, the upper part of the display
will show “P -”)
• the lower part of the display will show the day of the time of the next
switch-on; the day is visualised in 1 ... 7 format (number 1 corresponds
to Monday), the real time in the 24 h format (if no switch-on is
programmed, the lower part of the display will show “- - : - -”)
• the “delay” LED will be on
• the LED will be on.
12.3
Temporary modification of the next switch-on time
To access the procedure:
• make sure that the instrument is in the programmed switch-on status
and no procedure is in progress
• press
and
: the upper part of the display will show the label
of the program that will be started-up on switch-
on, the lower part will show the day of the week
and the time of the next switch-on; the indication
relative to the day and the “delay” LED will flash.
The day is displayed in the 1 ... 7 format (number 1 corresponds to
Monday), the time in the 24 hour format (hours:minutes)
To modify the day:
• press
or
within 15 s
• press
: the left part of the indication relative to the ignition time
will flash.
To modify the hour:
• press
or
within 15 s
• press
: the right part of the indication relative to the ignition time
will flash.
To modify the minutes:
• press
or
within 15 s
• press
: the label of the program that will started on switch-on
will flash.
To modify the program that will be started-up on switch-on:
• press
or
within 15 s
• press
: the “delay” LED will switch-on, after which the instrument
will exit the procedure.
To go back to the previous level:
• press
during the procedure.
To exit the procedure in advance:
• press
and
or do not operate for 15 s (any modifications will
not be saved).
The temporary modification of a switch-on is re-proposed also after a
power cut and has an exclusive effect on the immanent switch-on and
not on those previously set.
If ou pass to the programmed switch-on status or any other status, the
modification will not be re-proposed.
12.4
Exclusion of the next switch-on for the benefit
of another already programmed
• make sure that the instrument is in the programmed switch-on status
and no procedure is in progress
• press
and
for 1 s: the lower part of the display will show
the day of the week and the time of next switch-
on and the “delay” LED will flash.
The day is displayed in the 1 ... 7 format (number 1 corresponds to
Monday), the time in the 24 hour format.
• press
within 15 s to select another switch-on already
programmed
• press
: the “delay” LED will switch-on, after which the instrument
will exit the procedure.
To exit the procedure in advance:
• press
and
or do not operate for 15 s (any modifications will
not be saved).
The exclusion of a switch-on is re-proposed also after a power cut; the
switch-ons excluded are re-proposed in the following day and time
circumstances.
If you pass to the programmed switch-on status or any other status,
the exclusion will not be re-proposed.
11.2
Memorising a program
To access the procedure:
• make sure that the instrument is in stand-by status and that no
procedure is in progress
• press
and
: the lower part of the display will show “PrOG”
and “0” (it is the label of the zero program).
The label meaning is the following:
LABEL
MEANING
0
zero program
1
first program
2 ... 8
second ... eighth program
9
ninth program
-
no program used
To select a program:
• press
or
within 15 s (for example to select “7”).
If the program is already used, the top part of the display will show “bSY”.
To select the first cooking phase:
• press
: the upper part of the display will show flashing “F 1” (it is the
label of the first phase) and the lower part will show “- - - -”
• press
: the upper part of the display will show “F 1” and the
lower part will show flashing “- - - -”
• press
or
within 15 s (for example to select “COrE”).
If the pre-heating phase is not enabled (parameter r11 = 0), the “Gril”
label will not be displayed.
To modify the settings:
• operate as indicated in the respective procedure, i.e.:
- operate as indicated in the procedure stated in paragraph 4.3 for the
timed cooking phase
- operate as indicated in the procedure stated in paragraph 4.4 for the
core cooking phase
- operate as indicated in the procedure stated in paragraph 4.5 for the
steam cooking phase
- operate as indicated in the procedure stated in paragraph 4.6 for the
grill cooking phase
- operate as indicated in the procedure stated in paragraph 4.7 for the
continuous cooking phase
• press
for 1 s: the upper part of the display will again show flashing
“F 1” and the lower part the label of the cooking phase (in
the example “COrE”).
To select the successive cooking phases:
• repeat the procedure stated in this paragraph.
The upper part shows “Ch”.
To memorise the program:
• press
for 1 s: the upper part of the display will show “Ch” for
1 s, after which it will show “bSY”, the lower part will
show flashing “PrOG” for 4 s and the program label (in
the example “7”), after which “PrOG” it will switch-on.
To memorise another programmed, repeat the procedure given in this
paragraph.
To exit the procedure:
• press
and
or do not operate for 15 s.
To exit the procedure in advance:
• press
and
or do not operate for 15 s during the procedure
(i.e. before memorising the program: any
modifications will not be saved).
11.3
Starting a program in manual mode
• press
after having memorised the program
11.4
Start-up of a program on programmed switch-on
of the instrument
• press
before exiting the procedures stated in chapter 12 (i.e. after
having modified the minutes, for example, of the switch-
off time “H07” of the combination of days “1 - 5”): the
lower part of the display will show “PrOG” and “1” (it is
the label of the first program).
To select a program:
• press
or
within 15 s (for example to select “7”).
To display the information regarding the program:
• press
: the display and the LEDs will show the following
information in succession (for example), after which the
instrument will restore the normal display.
LED
DISPLAY
-
7 (upper part) and PrOG (lower parts; continuous ...)
the program selected
-
CorE (continuous ...)
the cooking phase (core)
and 1 150 (continuous ...)
the work set-point value is 150 °C/°F
and 2 100 (continuous ...)
the core set-point value is 150 °C/°F
-
Cont (continuous ...)
the cooking phase (continuous)
150
the work set-point value is 150 °C/°F
The display shows every setting for 1 s.
To exit the succession of settings:
• press
To confirm the selection of the program:
• press
the upper part of the display will again show the label of
the flashing switch-on time (in the example “H07”) and
the lower part will show the combination of days again (in
the example “1 - 5”).
If “-” is selected, on programmed switch-on of the instrument a
continuous cooking phase will be started.