EVCO EV9376J9 User Manual
Page 4

Evco S.p.A. • Code 1049376E00 • page 4/8
During the phase:
• the upper part of the display shows the established quantity with
parameter P5 (for predefined setting of the chamber temperature)
• the lower part of the display will show the “- - - -” indication
• press
and
to display the indication relative to the cooking
phase in progress for 2 sec in the lower part of
the display (“COnt”).
The phase remains active until it is interrupted.
To conclude/interrupt the phase:
• press
for 1 s:
To memorise the phase and its settings in a program:
• make sure the phase has ended
• press
and
for 4 s: the lower part of the display will show
“PrOG” and a flashing label relative to the first
program
• repeat the procedure stated in paragraph 11.2.
The instrument memorises the phase and its settings on condition that
another phase is not selected on conclusion of the phase.
4.8
Additional functions
4.8.1
Suspension/re-start of a timed cooking phase, of
a steam cooking phase and a grill cooking phase
• press
During the suspension:
• the lower part of the display will show flashing “PAUS”
• the temperature regulation output is switched-off
• the grill is switched-off.
• the airhole is switched-off
• the steam injector is switched-off
• the fan is switched-off
• the phase duration count is suspended.
4.8.2
Extension of a cooking phase on conclusion of
the same
• press
before interrupting the phase: the lower part of the display
will show “00” and the “timer” LED will flash
• press
or
within 15 s.
The duration of the extension can be set between 1 and 59 min.
• press
: the “timer” LED will stop flashing and will switch-on,
after which the instrument will exit the procedure and the
cooking phase will be re-started.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
To prolong the cooking phase further, repeat the procedure given in
this paragraph.
5
SETTINGS
5.1
Setting the utility managed by relay K3 and
relay K6
To access the procedure:
• make sure that the instrument is in stand-by status and that no
procedure is in progress
• press
and
for 4 s: the upper part of the display will show “PA”
• press
: the lower part of the display will show the corresponding
value
• press
or
within 15 s to set “743”
• press
• press
and
for 4 s: the upper part of the display will show
“dEF”
• press
or
to select “do3” or “do6”.
The label meaning is the following:
LABEL
MEANING
do3
utility managed by the third digital output (relay K3)
do6
utility managed by the sixth digital output (relay K6)
To modify the utility managed by an output:
• press
: the lower part of the display will show the corresponding
value.
The meaning of the values is the following:
VALUE MEANING
0
not used
1
vent
2
reversal of the direction of the fan
3
chamber light
4
steam generator
5
alarm
6
acoustics
7
on/stand-by
• press
or
within 15 s
• press
To exit the procedure:
• press
and
for 4 s:
5.2
Setting the day and the real time
• make sure that the instrument is in stand-by status and that no
procedure is in progress
• press
and
: the lower part of the display will show the day
of the week and the real time; the indication
relative to the day and the “clock” LED will flash.
The day is displayed in the 1 ... 7 format (number 1 corresponds to
Monday), the real time in the 24 hour format (hours:minutes)
To modify the day:
• press
or
within 15 s
• press
: the left part of the indication relative to the real time will flash.
To modify the hour:
• press
or
within 15 s
• press
: the right part of the indication relative to the real time will
flash.
To modify the minutes:
• press
or
within 15 s
• press
: the “clock” LED will switch-off, after which the instrument
will exit the procedure.
To go back to the previous level:
• press
during the procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
5.3
Setting the configuration parameters
To access the procedure:
• make sure that the instrument is in stand-by status and that no
procedure is in progress
• press
and
for 4 s: the upper part of the display will show “PA”
• press
: the lower part of the display will show the corresponding
value
• press
or
within 15 s to set “-19”
• press
or do not operate for 15 s
• press
and
for 4 s: the upper part of the display will show “SP1”
To select a parameter:
• press
or
To modify a parameter:
• press
: the lower part of the display will show the corresponding
value
• press
or
within 15 s
• press
or do not operate for 15 s.
To exit the procedure:
• press
and
for 4 s or do not operate for 60 s (any
modifications will be saved).
Cut off the power supply to the instrument after
modification of the parameters.
5.4
Restoring the default values (configuration
parameters and settings memorised in the
programs)
• make sure that the instrument is in stand-by status and that no
procedure is in progress
• press
and
for 4 s: the upper part of the display will show “PA”
• press
: the lower part of the display will show the corresponding
value
• press
or
within 15 s to set “743”
• press
or do not operate for 15 s
• press
and
for 4 s: the upper part of the display will show “dEF”
• press
: the lower part of the display will show the corresponding
value
• press
or
within 15 s to set “149”
• press
or do not operate for 15 s: the upper part of the display
will show flashing “dEF” for 4 s, after which “dEF” will
switch-on
•cut the instrument power supply off.
To exit the procedure in advance:
• press
and
for 4 s during the procedure (i.e. before setting
“149”: restore will not be carried out).
Make sure that the default values are appropriate.
6
GRILL
6.1
Preliminary considerations
The grill is switched-on in a cyclical way (the parameter c1 establishes
the cycle time; the parameter c11 establishes the duration of switch-on
of the grill, intended as a percentage of the time established with
parameter c1).
If the parameter r17 is set at 1, the grill will only be switched on once
before the conclusion of the grill cooking phase (for the time established
with the parameter c1).
The grill can also be switched-on/off in manual mode.
The grill can only be switched-on during the grill cooking phase.
6.2
Activation/deactivation of grill switch-on in
cyclical mode (only if parameter r17 is set at 0)
• make sure a grill cooking phase is in progress and that no procedure
is in progress
• press
for 4 s: the LED will switch-on and the grill will be on,
both for the time established with parameter c11, intended
as a percentage of the time established using parameter c1.
6.3
Grill switch-on in manual mode
• make sure a grill cooking phase is in progress and that no procedure
is in progress
• press
for 4 s: the LED will switch-on and the grill will be turned
on, both for the time established with parameter c1.
6.4
Grill switch-off in manual mode
• make sure no procedure is in progress
• press
for 4 s: the LED will switch-off.
7
AIRHOLE
7.1
Preliminary considerations
The airhole can be switched on in the following conditions:
• before the conclusion of the steam cooking phase (the time established
with parameter c5), for the time established with parameter c6
• in manual mode, for the time established with parameter c7 (both
during the pre-heating phases and during any cooking phase).
7.2
Airhole switch-on in manual mode
• make sure that the instrument is in on status and that no procedure
is in progress
• press
: the LED will switch-on and the airhole will be turned
on, both for the time established with parameter c7.
If the airhole is not managed by any digital output, pressing the
key will cause the “no” indication to be shown in the lower part of the
display for 1 s.
7.3
Airhole switch-off in manual mode
• make sure no procedure is in progress
• press
: the LED will switch-off.
8
STEAM INJECTION
8.1
Preliminary considerations
The steam injector can be switched-on in the following conditions:
• during the steam cooking phase, according to the method established
with parameter t0:
- if the parameter t0 is set at 0, pressing the
key will cause the
injection of the steam for the time established with parameter t2 or
for the entire duration that the key is pressed; the parameter t1
establishes the minimum time that will pass between the two
successive injections.
- if the parameter t0 is set at 1, pressing the
key will enable the
automatic injection of the steam (in cyclical mode: the parameter t2
establishes the duration of injector switch-on and the parameter t1
establishes the duration of switch-off).
• in manual mode, for the time established with parameter t2 or for
the entire duration of the manual action (both during the pre-heating
phase and during any cooking phase).
Via the multifunction input it is also possible to cause the same effect
by pressing the
key in remote mode.
The steam injection is subordinate to the status of the fan and the
steam generator (see chapters 9 and 10).
8.2
Switch-on of the injector in manual mode (only
if the parameter t0 is set at 0)
• make sure that the instrument is in on status and that no procedure
is in progress
• press
: the LED switches on and the injector will be activated,
both for the time established with parameter t2 or for the
entire duration that the key is pressed.
The injector cannot be switched-off in manual mode.
8.3
Enabling of the automatic injection of the steam
(only if the parameter t0 is set at 1)
• make sure the steam cooking phase is in progress and that no
procedure is in progress
• press
: the LED will switch-on and the injector will be switched-
on in cyclical mode according to that established with the
parameters t1 and t2 (until the key is pressed again).
9
FAN
9.1
Preliminary considerations
The fan can be on during the continuous mode during the pre-heating
phase and during any cooking phase.
If the parameter F2 is set at 1, the fan output and the inversion output
of the direction of fan movement will be switched-on in cyclical mode
(the parameter F4 establishes the duration of every direction of
movement. The parameter F3 establishes the time between switch-off
of one output and the switch-on of another).
It is also possible to reverse the direction of movement of the fan in
manual mode.
If parameter r16 is set at 1, during switch-off of the fan, the output for
regulation of the temperature will remain off.
If parameter t5 is set at 0, the steam injection will be allowed on condition
that the fan is on. If parameter t5 is set at 1,the steam injection will be
allowed on condition that the fan is off (i.e. during switch-off of the fan;
in this case the injector can only be switched-on in manual mode).
9.2
Inversion of the direction of fan movement in
manual mode
• make sure that parameter F2 is set at 1 and that no procedure is in
progress
• press
for 4 s: the fan will remain off for the time established with
parameter F3, after which it will be switched back on.
If the fan movement direction reversal is not managed by any digital
output, pressing the
key will cause the “no” indication to be shown
in the lower part of the display for 1 s.
10
STEAM GENERATOR
10.1
Preliminary considerations
The steam generator allows to subject the injection of the steam at its
own status.
Pressing the
and
keys will cause the steam generator to switch-
on and pressing again causes switch-off; the injection of steam is
allowed on condition that the steam generator is on.
The steam generator can be on during the pre-heating phase and
during any cooking phase.
If the steam generator is not managed by any digital output, pressing
the
and
key will cause the “no” indication to be shown in the
lower part of the display for 1 s.
11
PROGRAMS MANAGEMENT
11.1
Preliminary considerations
The programs allow to memorise combinations of several cooking
phases.
On program start-up the instrument will function with the settings it
has memorised.
It is possible to combine up to 5 cooking phases (i.e. plan that on
conclusion of a cooking phase a different type is started automatically)
for every program. It is possible to memorise up to 10 programs.
If the parameter r11 is set at 1, the first cooking phase is preceded by a
pre-heating phase (see paragraph 4.2).
The programs can be started in manual mode or on programmed
switch-on of the instrument (see chapter 12).
The modification of the settings memorised in a program during the
execution of the same is not re-proposed on the successive start-up of
the same program.