beautypg.com

Installation and configuration, Installing the driver, Loading the driver – Comtrol RocketModem Driver Installation for Novell NetWare User Manual

Page 3: Initialize and configure, Initialize the

background image

Installing the Driver

3

Installation and Configuration

Use this section to install and configure the RocketPort/RocketModem driver (

AIORCKT.NLM

) for the Novell

NetWare operating system.

Installing the Driver

This discussion assumes that you have installed the RocketPort or RocketModem in the server.

Note: You must have NetWare Connect or MPR installed before installing the driver files. If NWC or MPR are

not already installed, do so before continuing.

To install the AIORCKT.NLM driver:

1.

Login from a client system with administrator rights.

2.

Copy the driver files to the /system directory on the server, which is found in the sys volume.

The /aio directory is created during NWC/MPR installation. The drive letter for the volume varies,
depending on network configuration and drive mapping.

3.

If NetWare Connect (NWC):

a.

Copy the

AIORCKT.NLM

file to the /system directory.

b.

Copy the

AIORCKT.ADI

file to the /system/aio directory.

c.

Copy other files as desired.

4.

If NetWare Internet Access Server or Multi-Protocol Routing (NIAS/MPR):

a.

Copy the

AIORCKT.NLM

and

AIORCKT.ADI

files to the /system directory.

b.

Copy the

AIORCKT.ADI

file to /system/aio directory.

Note: While this may appear redundant, the file is needed in both locations in order for MPR

configuration to work correctly.

c.

Copy other files as desired.

You are now ready to load the driver.

Loading the Driver

You can load

AIORCKT.NLM

either manually, by command line from the server console, or automatically,

through

AUTOEXEC.NCF

when the server boots.

If you are using NetWare Connect, you must load the driver manually before configuring NetWare
Connect.

If you are using NIAS/MPR, the driver is loaded as part of the configuration process, and you must not load
the driver manually. Instead, go to the appropriate discussion:

-

NIAS/MPR Installation and Configuration for NetWare 4.x

-

NIAS/MPR Installation and Configuration for NetWare 5.x

To load the driver manually, enter this command line for each board. The

AIORCKT.NLM Parameters

table

provides a description of each parameter.

load AIORCKT port={IOADDR} {PCI} [{FINDPCI} node={NNN} name={SSS} nports={PP} {fastbaud} {hyperbaud}
{mcc
}=nnn or cccc]

Note: Parameters within the [brace set] are optional. If you have a combination of PCI and ISA boards

installed, load the drivers for the PCI boards before loading the drivers for the ISA boards.

PCI Example:

The following is an example of a PCI load command for a RocketPort Octacable:

load AIORCKT PCI

ISA Example:

The following is an example of an ISA load command for a RocketPort Quadcable:

load AIORCKT port=180 nports=4