Q\ replace with wire cover, Installation instructions – GE C2S985SETSS User Manual
Page 49
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Installation Instructions
Read these instructions completely and carefully.
\5\ Replace the Power Cord (Optional) Continued
Perform this step only if the power cord shipped on the range does not match your wall receptacle.
4-Wire Conduit Installation Option
Remove the strain relief clamp from the bracket.
2
m
Assemble the squeeze connector (obtained locally),
matching the diameter of your conduit, in the bracket
hole. Insert the conduit through the squeeze connector.
Allow enough slack to easily attach the wires to the
terminal block.
NOTE- Do not install the conduit without a squeeze
connector.
Insert the ground bare wire tip between the range frame
and the ground plate (removed earlier) and secure it in
place with the ground screw (removed earlier). Insert the
bare wire (white/neutral) tip through the bottom center of
the terminal block opening. Insert the two side bare wire
tips into the lower left and the lower right terminal block
openings. Tighten the screws until the wire is firmly secure
(approximately 20 inch-lbs.).
NOTE Make sure the wire is completely inserted into the
terminal block and a secure connection is made.
Secure the squeeze connector in place in the bracket by
tightening the squeeze connector screws.
NOTE ALUMINUM WIRING:
Aluminum building wire may be
used but it must be rated for the correct amperage and voltage
to make connection.
Wire used, location and enclosure of splices, etc., must
conform to good wiring practices and local codes.
Q\ Replace with Wire Cover
Replace the wire cover on the range back by sliding its right
edge under the retaining tab and replacing the two screws
removed earlier. Make sure that no wires are pinched between
the cover and the range back.
49