A&D Weighing AD-4407 User Manual
Page 59
AD-4407 Weighing Indicator
Page
57
15.
15.
15.
15. Relay Output & Control Input (OP
Relay Output & Control Input (OP
Relay Output & Control Input (OP
Relay Output & Control Input (OP-
-
-
-05)
05)
05)
05)
Replacing the RS-232C interface with this option, 3-relay outputs and 3-control inputs
can be used with the RS-232C interface of this option.
RS-232C functions are the same as the RS-232C interface described in “13. RS-232C
Interface”.
The solid state relays output the result of comparison.
The control inputs can control the indicator from an external terminal just like the front
panel key operations.
Set the external control function at f13 - f15 of the F-Functions.
When connecting each function pin to the common pin, the indicator makes the action.
Keep a signal width of more than 100ms for the On-time and Off-time.
ON(Make)
OFF(Break)
Pin co
Pin co
Pin co
Pin connections and Circuits
nnections and Circuits
nnections and Circuits
nnections and Circuits
Function Pin No. Signal name
Direction
Description
1 TXD
Output Transmit
data
2 RXD
Input Received
data
3
DSR
Output
Data set ready
RS-232C
4 SG
-
Signal
ground
5
HI
Output
Relay output HI
6
OK
Output
Relay output OK
7
LO
Output
Relay output LO
Relay
output
8
COM(out)
-
Relay output common
9
EXT1
Input
Control input 1 (f13)
10
EXT2
Input
Control input 2 (f14)
11
EXT3
Input
Control input 3 (f15)
Control
input
12
COM(in)
-
Control input common
FG
13
FG
-
Frame ground (case)
15. Relay Output & Control Input (OP-05)
6:& 4:& &54 5) *+ 1- .1 %1/Q ':6
Relay output
RS-232C
Ʈ
':6 ':6 %1/K ()
Control input
Case
K
Relay specifications
Maximum voltage
DC50V
Maximum current
DC100mA
Maximum resistance
8
9
More than 100ms
More than 100ms