A&D Weighing AD-4407 User Manual
Page 29
AD-4407 Weighing Indicator
Page
27
Data Output *: Initial
settings.
Item
Parameter
Description
** 0
No data output
1
Analog output
Set f31, 32, 33
2
Serial output
f30
Data output
3
Serial output (Zero suppressing)
RS-232C,
RS-422/485
Analog Output *:
Initial
settings.
Item
Parameter
Description
* 0
Display data
1
Gross data
f31
Output data
2
Net data
f32
Weight value at 4mA output
-999999 to 999999 (Initial setting is 0)
f33
Weight value at 20mA output
-999999 to 999999 (Initial setting is
10000)
Polarity is
changed by
pressing the +/-
key.
Serial Data Format
Item
Parameter
Description
x 0
Terminator
x 1
Device ID (selected at f06)
x 2
Code number
x 3
Data number *
x 4
Result of comparison
x 5
(Reserved)
x 6
(Reserved)
x 7
Accumulated value
x 8
Accumulation count
x 9
Stable / Over
x a
Displayed weight
x b
Gross weight
x C
Net weight
x d
Tare weight
x e
Weight type (
G /N / T
, refer to Cf06)
f34
[Type3]
Serial data format 1
Initial value
19, 2e, 3a 4f e50
f35
[Type3]
Serial data format 2
Initial value
17 2f e30
x f
Weight unit (cf. Cf07)
ZERO
key :
Order of output
(1 to 999)
“Exxx” indicates
the end of data
to output
NET/GROSS
key:
Expand or
shorten output
data length
0
-
9
,
A
-
F
key:
output data
1 Comma of the parameter display indicates that the comma (f46 0, semi-colon for
f46 1) is output after the data. To turn this mark on and off, press the
9
key while
pressing
NET/GROSS
key.
Output of initial settings of f34(19, 2e, 3a 4f e50) is like “ST,GR,+12345.6kg”.
2 The data number *(parameter 3) increments automatically with each serial data
output from 1 to 99999 (the next after 99999 is 1). The starting number can be set
by the keys.
Press the
CODE(1)
key while pressing the
key at weight display, the display
changes to data r then r xxx. “xxx” is the next data number. Using the
0
-
9
keys to
enter the number and pressing the
ENTER
key to store the number and return to
weight display.
6.2.
F-Functions