A&D Weighing AD-4407 User Manual
Page 27
AD-4407 Weighing Indicator
Page
25
External Input
Item
Parameter
Description
** 0
Not used (No function)
1
ZERO key
2
TARE key
3
NET/GROSS key
4
ON/OFF key
5
PRINT key, ENTER key
6
(No function)
7
Serial data output (Format 1)
8
Serial data output (Format 2)
9
Accumulation (M+)
10
Start batching
11
Stop batching
12
“Over” signal, Gross over and display data out when ON
13
NET weight display when shorting the terminal.
14
Accumulated data display when shorting the terminal.
15
Execute comparison when shorting the terminal.
16
Display by the second unit when shorting the terminal.
17
All keys are enable when shorting the terminal.
(Ignores f12 temporary)
18
Inhibit memory code reading when shorting the terminal.
19
Start averaging to hold
f13
EXT1
Function selection of
external input
20
Release holding data
0 to 17, 19 and 20 Same as f13
f14
EXT2
18
Memory cord (BCD 1)
0 to 17, 19 and 20 Same as f13
f15
EXT3
18
Memory cord (BCD 2)
*: Initial
settings.
Accumulation
Item
Parameter
Description
10 11 Do not add(0)/Add(1)
20 21 Manual(0)/Automatic(1)
30 31
+
Only(0) / Both +/- (1)
f20
[Type2]
Accumulation Mode
40 41 OK only(0)/All data(1)
Left: Sub item, select using the
ZERO
key
Right: Setting, select using the
0
,
1
keys
Initial settings: 10, 21, 31, 41
0
Add data anytime
** 1
Above 5 d
2
Above 10 d
3
Above 20 d
f21
Inhibit region for
accumulation
4
Above 50 d
The selection of the inhibit region
for accumulation.
Do not set f21 0 when Auto
accumulation (f20 21).
d:
division (weighing interval) of first range.
*:
Initial settings.
6.2.
F-Functions