A&D Weighing AD-4407 User Manual
Page 37
AD-4407 Weighing Indicator
Page
35
9.1.1. Using
Code
Memory
Step 1 Pressing the
CODE
key at the weight display, Cd x is displayed with the
present code memory number x blinking. Using the following keys:
0
-
4
key..................The key to input the code memory number.
CLEAR
key ..............The key to reset the code memory number (0).
+/-
key .....................The key to copy the data set to other code memory number.
Proceed to step 3.
ESC
key ..................The key to return to the weight display.
ENTER
key..............The key to set the code memory number, stop blinking.
Proceed to step 2.
Step 2 The code memory number is set and the blinking stops. Using the following keys:
SETPOINT
key ........The key to set the comparison data. Refer "10.1.2. Setting
Upper/Lower Limit Value".
PT
key.....................The key to set the preset tare data. Refer "7.1.2. Digital Input".
ESC
key ..................The key to return to step 1.
ENTER
key..............The key to store the selected code memory number's data
and to return to the weight display.
Step 3 Copy is displayed for 2 seconds and then C x-y is displayed with “y” blinking.
Using the following keys:
0
-
4
key..................The key to input the code memory number to be stored.
ESC
key ..................The key to return to step 1.
ENTER
key..............The key to copy number x's data to number y and to return
to step 1.
Changing the Code Memory Number by External Input
The code memory number can be changed by external input from OP-05 or
OP-08.
Set F14 and F15 to 18. (OP-08 has only one input; set F15)
F13=18 : Inhibit reading EXT.2 and EXT.3 to prevent unintentional reading when
switching the codes.
EXT.2 (f14) EXT.3
(f15)
Code Memory number
ON ON
1
OFF ON
2
ON OFF
3
OFF OFF
4
9. Code Memory