beautypg.com

Wiring the rs-232c port, Installing the n-r2, Surrounding space – KEYENCE N-R2 User Manual

Page 3: Installation precautions

background image

3

E N-R2-IM

Wiring OUT1

to 4

Wiring the RS-232C port

Pin layout of the RS-232C port

Wiring the RS-232C cable

When connecting to the PC, wire as shown below.

* It can be connected with Keyence’s optional cable OP-27937 (2 m).

Surrounding space

Install the N-R2 vertically.
When the installation direction changes,
provide adequate surrounding space so
that heat does not build up.

For ventilation, maintain a space of 50mm
or more from the top and bottom of the N-
R2. As long as the N-R2 is the only
source of heat generation, the N-R2 can
be installed without space on the right
and left sides.
Provide a space of 80 mm or more in front
of the N-R2 to connect the BL head.

50 mm or more on the top and bottom; no space is required on the

right and left sides

Installation precautions

When installing the N-R2, do not block the ventilation slots on the
top and bottom of the unit. Otherwise, heat builds up inside the
unit, causing product failure.

If the temperature of the N-R2 will foreseeable exceed the upper
limit of the operating temperature (50

°C), take the appropriate

measures such as performing forced air cooling or ensuring
proper ventilation so that the temperature does not exceed the
upper limit of the normal operating temperature (50

°C).

Installing and removing the N-R2 to and from the DIN

rail

Installing the N-R2 to the DIN rail

1

Lower the mounting tab on the back of the N-R2.

Check that the mounting tab is placed in the position shown in the
following diagram.

2

Install the N-R2 to the DIN rail as shown in the following
diagram.

Pin number

Symbol

Description

Signal direction

2

RD (RXD)

Data reception

Input

3

SD (TXD)

Data transmission

Output

4

ER (DTR)

Connected to Pin 6 internally

Output

5

SG

Signal ground

6

DR (DSR)

Connected to Pin 4 internally

Input

7

RS (RTS)

Transmission request (always
ON)

Output

8

CS (CTS)

Transmission permitted

Input

Installing the N-R2

OUT1 to 4

OUT
COM

Load

Circuit diagram

Load

Load

Load

Load

In

te

rn

al

c

irc

ui

t

2

1

3 4 5

6 7 8 9

D-sub 9-pin (male)
DTE specification (terminal definition)
#4-40 screw (female)

2

3

7

8

4

6

5

2

3

7

8

4

6

5

RD

SD

RS

CS

ER

DR

SG

RD

SD

RS

CS

ER

DR

SG

Connector

case

DOS/V PC

Connector
case

N-R2

D-sub 9-pin

(female)

#4-40 screw

D-sub 9-pin

(female)

#4-40 screw

Top

Bottom

80 mm or more
from the front

80 mm

50 mm

50 mm

Mounting tab

DIN rail

Protrusion

DIN rail

Protrusion

Mounting tab

1. Hook

2. Push