Part names and functions, System configuration figure, Connection and wiring methods – KEYENCE N-R2 User Manual
Page 2: Connecting the code reader, Connecting the power supply, Layout and wiring of the i/o terminal block, Kv -b1 6xc
2
E N-R2-IM
■ Connecting the code reader
Connect the code reader to the head port of the N-R2.
Pin layout of the head port
■ Connecting the power supply
Connect the 24 VDC power supply to the power terminal of the N-R2.
The dimensions of crimp contacts used for wiring should be as follows:
■ Layout and wiring of the I/O terminal block
•
Layout of the I/O terminal block
•
Wiring IN1 and IN2
Part Names and Functions
Number
Name
Function
1
Head port
Used to connect the head.
2
Power LED
Lights when the power is ON.
3
Communication status
LED
Monitors the status of communication with the
head.
4
RS-232C port
Used to connect to the host (personal
computer, PLC).
5
I/O status LED
Monitors the ON/OFF status of I/O terminals.
6
I/O terminals
Used to connect I/O signal lines of control
units.
7
Power terminal
Terminal for 24 VDC power supply input.
8
DIN rail mounting tab
A tab for mounting the DIN rail.
System Configuration Figure
Connection and Wiring Methods
Pin
number
Name
Signal name
Signal
direction
1
OUT1
OUT1 input
Input
2
OUT2
OUT2 input
Input
3
RXD
RS-232C Receive
Input
4
RTS
RS-232C Receivable
Output
5
OUT4
OUT4 input
Input
6
IN2
IN2 output
Output
7
TXD
RS-232C Transmit
Output
8
CTS
RS-232C
Transmittable
Input
9
OUT3
OUT3 input
Input
10
IN1
IN1 output
Output
11
+5V
+5V power supply
Output
8. DIN rail mounting tab
1. Head port
2. Power LED
3. Communication
status LED
4. RS-232C port
5. I/O status LED
6. I/O terminals
7. Power terminal
KV
-B1
6XC
Head port
OUT1 to 4
IN1
Head
BL Series
SR Series
Personal
computer
PLC
Timing sensor
RS-232C port
3
7
4
8
5
1
2
9
11
12
6
10
Round 12-pin jack
12
GND(SD)
Common GND
-
CAUTION
Install and remove connection cables with the power
disconnected.
CAUTION
Using a power supply other than 24 VDC may cause
product failure.
Terminal
Dimensions
Round Terminal
a: 6 mm Max.
Y terminal
a: 6 mm Max.
Item
Description
Wire size
AWG14-22
Tightening torque
0.49 N·m (4.34 lbf·in)
Wire material
Copper
Wire type
Stranded wire
Electric wire
temperature rating
+60
°C max.
Note
• For connection, use stranded copper wire having a
gage of AWG16 to 26 and temperature rating of 60
°C
or higher.
• The tightening torque is 0.19 N·m (1.7 lbf·in).
Power supply
24V+10%
-20%
Twist pair cable
I/O terminal
block
Circuit diagram
IN1, IN2
INCOM
Internal
circuit