beautypg.com

Cables, Connecting the power i/o cable of the sensor – KEYENCE IV Series User Manual

Page 6

background image

6

IV Series (Sensor) - IM_E

Cables

Connecting the power I/O cable of the sensor

1

Adjust the pins of the connector for the power I/O

cable and pin connection of the cable connector,

and connect the cable to the sensor.

Adjust the pins and the

pin connection

2

Tighten the connector by turning the screw-on

connector in the clockwise direction.

Tightening torque of the screws needs to be 1.0 to 1.5 N·m.

When connecting the connector, insert it

without tipping and tighten it well. If the

tightening is weak, it may cause a bad

connection and vibration can loosen the

connector. Also, the enclosure rating may

not be maintained with loose connection.

* Indication is retightening approximately

90° to 120° with tools such as pliers

after tightening with hands.

3

Wire each cable according to its intended purpose.

z

z

Selecting NPN output

When NPN is selected in I/O format

DC24V

IN

OUT

(NPN)

Black/White/Gray/

Orange

(OUT)

Brown (DC24V)

y

Black (OUT1) / White (OUT2) /

Gray (OUT3) / Orange (OUT4)

y

Pink (IN1 : External trigger) / Yellow (IN2) /

Light Blue (IN3) / Purple (IN4) / Green (IN5)

/ Red (IN6)

Use it by assigning the optional function to

OUT1 to OUT4 and IN2 to IN6.

External device

Load

Blue (0V)

Drain wire (FG)

Pink/Yellow/

Light Blue/Purple/

Green/Red

(IN)

z

z

Selecting PNP output

When PNP is selected in I/O format

DC24V

IN

OUT

(PNP)

Black/White/Gray/

Orange

(OUT)

Brown (DC24V)

y

Black (OUT1) / White (OUT2) /

Gray (OUT3) / Orange (OUT4)

y

Pink (IN1 : External trigger) / Yellow (IN2) /

Light Blue (IN3) / Purple (IN4) /Green (IN5)

/ Red (IN6)

Use it by assigning the optional function to

OUT1 to OUT4 and IN2 to IN6.

External device

Load

Blue (0V)

Drain wire (FG)

Pink/Yellow/

Light Blue/Purple/

Green/Red

(IN)

Wiring

color

Name

Assigning

default value

Description

Brown DC24V -

+ side of power

Blue 0V

-

- side of power

GND of input-output cable

Black OUT1

Total judge

(N.O.)

Output assignable

function

y

Total Status

y

Tot.StatusNG

y

RUN

y

BUSY

y

Error

y

Pos. Adj.

y

Judge result of each

tool (Tool 1 to Tool 16)

y

Result of the logical

operation of each tool

(Logic 1 to Logic 4)

y

OFF (not used)

White OUT2

BUSY (N.O.)

Gray OUT3

Error (N.O.)

Orange OUT4

OFF

Pink IN1

External

trigger ↑

Set external trigger.

Activation timing (↑) or

deactivation timing (↓)

can be set.

Yellow IN2

OFF

Input assignable function

y

Program bit0 to bit4

y

Clear error

y

External master

y

OFF (not used)

Light Blue IN3

OFF

Purple IN4

OFF

Green IN5

OFF

Red IN6

OFF

Drain FG

-

Insulated frame

Cable

specification

y

Brown/Blue/Black/White/Gray/Orange

: AWG25

y

Pink/Yellow/Light Blue/Purple/Green/

Red : AWG28

y

With braided shield cable (with drain cable)

The output assignment, N.O./N.C., and input line

assignment can be changed. For details, refer to

the User's Manual.

y

Individually insulate the non-used input-

output cables.

y

For input cables of this sensor, connect with

non-contact output (transistor output/SSR

output). For contact output (relay output),

incorrect input may be operated due to the

contact bouncing in the system.