Measures to be taken when an abnormality occurs, Precautions on installation, Precautions on regulations and standards – KEYENCE IV Series User Manual
Page 2: Ul certification, Ce marking, Checking the package contents
2
IV Series (Sensor) - IM_E
y
For instructions
y
Do not turn OFF the power while setting the
items or saving the settings. Otherwise, all
or part of the setting data may be lost.
y
Do not let water, dust or oil stick to the
camera/light of the sensor. Failure to do so
may cause a malfunction.
yWhen this product becomes dirty, do not rub it with
a wet cloth, benzene, thinner, or alcohol. Doing so
may change the color or shape of the unit.
yIf the unit is heavily contaminated, disconnect
all the cables including the power supply cable,
wipe off the dirt with a cloth soaked with mild
detergent, and then wipe with a soft dry cloth.
y
For external master image registration
When the external master image registration is used
frequently, set "Write ROM when registering external
master" of the input option to "No" for nonvolatile
memory protection of the internal sensor. When the
option is set to "Yes", the nonvolatile memory is
guaranteed to write for 100,000 times.
y
For automatic focus function
yAutomatic focus function is used for adjusting
the focusing position at the time of installation.
This will not activate during the operation.
y
Focusing position can be registered in each
program. The program configurations are
guaranteed to switch for 100,000 times. If the
focusing position does not need to change
for each program, set "AF Adjustment Pos"
to "Common" for extending the life-span.
y
Do not apply shock or vibration during the
focusing position adjustment . Failure to
do so may cause a product damage.
Measures to be taken when an abnormality occurs
In the following cases, turn the power OFF
immediately. Using the IV Series in an abnormal
condition could cause fire, electric shock, or
malfunction. Contact our office for repair.
y
If water or debris enters the IV Series.
yIf the IV Series is dropped or the case is damaged.
y
If abnormal smoke or odor emanates from
the IV Series.
Precautions on installation
yTo use this product correctly and safely, avoid
installing it in the following locations. Failure to do
so may cause fire, electric shock, or malfunction.
y
Outdoors
y
Altitude above 2000 m
y
Locations that are humid, dusty or poorly
ventilated
y
Locations where the temperature is high
such as those exposed to direct sunlight
y
Locations where there are flammable or
corrosive gases
y
Locations where the unit may be directly
subjected to vibration or impact
y
Locations where water, oil, or chemicals
may splash onto the unit
y
To improve the anti-noise feature, install
the unit following the precautions below.
Otherwise, a malfunction may occur.
y
Mount the sensor onto the insulated
attached mounting adapter.
yGround the FG cable (drain cable) of the sensor.
y
Do not mount the unit in a cabinet where
high-voltage equipment is already installed.
yMount the unit as far from power lines as possible.
y
Separate the unit as far as possible from the
devices that emit strong electric or magnetic
field (such as solenoid or chopper).
y
Separate the I/O signal line from the power
line or high-voltage line.
y
For power supply
yNoise superimposed on the power supply could
cause malfunction. Use a stabilized DC power
supply configured with an isolation transformer.
y
When using a commercially available
switching regulator, be sure to ground the
frame ground terminal.
y
Devices including this unit are precision
components. Do not apply shock or vibration.
y
When connecting to a network, let engineers
who are knowledgeable about networks
handle it.
Precautions on Regulations and Standards
UL Certification
This product is a UL/C-UL Listed product.
y
UL File No. E301717
y
Category NRKH, NRKH7
Be sure to consider the following specifications when using
this product as a UL Listed product.
y
Use a power supply with Class 2 output defined in NFPA70
(NEC: National Electrical Code).
y
Power supply/ External input/ Control output shall be
connected to a single Class 2 source only.
y
Use with an over current protection device which is rated
24 V or more and not more than 1 A.
y
Enclosure Type 1 (Based on UL50)
CE Marking
Keyence Corporation has confirmed that this product
complies with the essential requirements of the applicable
EC Directive, based on the following specifications. Be sure
to consider the following specifications when using this
product in the Member State of European Union.
z
z
EMC Directive (2004/108/EC)
y
Applicable Standard EMI: EN60947-5-2, Class A
EMS: EN60947-5-2
y
The length of power/IO cable, Ethernet cable and
Monitor cable must be less than or equal to 30m.
Remarks:
These specifications do not give any guarantee that the
end-product with this product incorporated complies with the
essential requirements of EMC Directive. The manufacturer
of the end-product is solely responsible for the compliance
on the end-product itself according to EMC Directive.
z
z
Low-Voltage Directive (2006/95/EC)
y
Applicable Standard: EN62471
Checking the Package Contents
Sensor
y
IV-500C
y
IV-500CA
y
IV-150M
y
IV-150MA
y
IV-500M
y
IV-500MA
y
IV-2000M
y
IV-2000MA
Sensor x 1
Mounting adapter x 1
Screw for mounting adapter x 1
Flathead screwdriver x1
(Manual focus type only)
Waterproof cap for Ethernet
connector x 1
Instruction Manual x 1 (This manual)
The mounting adapter is mounted on the monitor in the
default factory setting.