Page 9

background image

‐ 9 ‐

www.keyence.com

KEYENCE CORPORATION. Vision System Division

4

【Note】

"User settings" and "Defaults" can be selected, but if you choose
"Defaults", the items below will automatically return to their default
setting (standard setting) if they are changed. Be sure to use "User
settings". These specifications only apply to CX Programer Ver. 6 (as
of November 2010).

Select [PLC] > [Transfer] >[To PLC].

5

Set the following settings to the values set
for the CV-X Series Global Settings.

Data length: 8 bits
Stop bits: 1 bit
Parity: Even
Baud rate: 115200 bps
Protocol macro Transmission method:

Full-duplex

Open [IO Table and Unit Setup] on the left side of the screen, and register the serial communication unit in an
empty slot. Double-click the registered serial communication unit (CJ1W-SCU41 in this example) to edit the