Select [PLC] > [Transfer] >[To PLC].
5
4
Open [IO Table and Unit Setup] on the left side of the screen, and register the Ethernet link unit in an empty slot.
Double-click the registered Ethernet link unit (CJ1W-ETN21 in this example) to edit the parameters.
Configure the following settings in [Edit Parameters].
1. For [FINS/UDP Port], select "9600", the default value (the default value is also 9600 for CV-X).
2. Set [IP Address/Subnet Mask]. Enter the "IP Address" set in CV-X Global Settings.
3. Enter the CV-X NODE No. and IP Address into [IP Address Table] (the default CV-X NODE No. of 001 is recommended).
4. Set [Port No.] to 0.
After completing the settings, press "OK".
See also other documents in the category KEYENCE Lighting:
- GL-R Series (12 pages)
- GL-RHG Series (12 pages)
- GL-RHG Series (136 pages)
- GL-T11R (8 pages)
- SL-U2 (2 pages)
- SL-V Series (10 pages)
- SL-V Series (168 pages)
- SL-C Series (1 page)
- SL-C Series (54 pages)
- SL-M Series (8 pages)
- SL-T11R (6 pages)
- SL-VH1S (60 pages)
- SL-VHS Series (10 pages)
- SL-CHG Series (54 pages)
- SL-CHS Series (54 pages)
- SL-R11 (42 pages)
- SL-R11E (46 pages)
- SL-R12EX (76 pages)
- SJ Series (1 page)
- SJ-H Series (14 pages)
- SJ-HA Series (12 pages)
- SJ-HS/HW/HM (2 pages)
- SJ-F2000 Series (4 pages)
- SJ-F031 (10 pages)
- SJ-F300 Series (14 pages)
- SJ-F100W/100/010 (56 pages)
- SJ-M400 (14 pages)
- SJ-M100 (16 pages)
- SJ-M201 (16 pages)
- SJ-M300 (14 pages)
- CA-CNX10U (4 pages)
- CA-DC21E (2 pages)
- CA-HX048C (2 pages)
- CA-HX200C (2 pages)
- CA-HX500C (2 pages)
- XG Series (22 pages)
- XG VisionTerminal (58 pages)
- XG-8000 Series (12 pages)
- XG-8700T (12 pages)
- XG-7000 Series (8 pages)
- CA-H2100C (2 pages)
- CA-U4 (2 pages)
- CV-X Series (20 pages)
- CV-X Series (24 pages)
- CV-X Series (16 pages)