Establishing the plc-link – KEYENCE CV-X Series User Manual

Page 7

background image

KEYENCE CORPORATION. Vision System Division

‐ 7 ‐

www.keyence.com

1

Checking the Global Settings of the CV-X Series

On the "Global" menu, select [Communications & I/O] > [PLC-Link].

2

Select "OK" to close the "PLC-Link" setting screen and then restart the controller.

Configure the PLC‐Link settings.

Mode: PLC- Link (RS- 232C)
PLC Type: SYSMAC CJ/CS1/CP1 Series
Baud Rate: 115200
Stop Bit: 1
Parity Bit: Even
Flow Control: None
Data Length: 8- bit (fixed)
* The above is a setting example. Change
the settings according to the target device.

Decimal Point: Fixed- point

Command Execute Event: Polling
Command Complete Address (bit): 00003
Command Address: 00100
Command Result Address: 00200
Result Output Address: 00500
Result Ready Address (bit): 00000
Result Ack Address (bit): 00001
Acknowledge result output completion:
Checked
Enable Handshake: Unchecked

2. Establishing the PLC-Link

(RS-232C PLC-Link) [SYSMAC CJ Series]

This section describes how to establish the PLC‐Link.

[Important] If it fails, follow this manual to configure the settings and check the operations.

Confirm that it operates properly, and change settings if necessary.