Controlling the controller – KEYENCE CV-X Series User Manual

Page 9

background image

KEYENCE CORPORATION. Vision System Division

‐ 9 ‐

www.keyence.com

3. Controlling the Controller

(EtherNet/IP)

[Keyence KV Series]

1. Checking the Global Settings of the CV-X100 Series

5

Restart the controller.

1

From "Global", select "Communications & I/O" -

"EtherNet/IP".

Controlling the Controller

2

Click "Set" in "Data Settings".

The "EtherNet/IP Communication Data Structure"

screen appears.

3

Left-click "View List" in "Send-Data" and "Receive-

Data" to check the status of byte address and bit

address allocation for the items that are required

for controller control.

Receive-Data (PLC to Controller: OUT)
•Command request flag: Turns OFF→ON when a

command is executed (bit).

•Command Number: Sets the command No. of the

command to execute (double word).

•Command Parameter#: Sets the No. # argument

for the command (word). (Whether or not there

are arguments depends on the command.)

Send-Data (Controller to PLC: IN)
•Command complete flag: Turns ON when the

command process is completed (bit).

•Command error flag: Turns OFF when the

command process is completed, and ON when

a failure occurs (bit).

•Command ready flag: Turns ON when ready to

receive the command process (bit).

•Command Result: Sets the command execution

results (0: Success, : Failure)

(double word).

•Command Data#: Sets the command No. #

response data (word). (Whether or not there is

response data depends on the command.)

4

Click "OK".

The changed settings are saved.