Controlling the controller – KEYENCE CV-X Series User Manual
Page 9
KEYENCE CORPORATION. Vision System Division
‐ 9 ‐
www.keyence.com
3. Controlling the Controller
(EtherNet/IP)
[Keyence KV Series]
1. Checking the Global Settings of the CV-X100 Series
5
Restart the controller.
1
From "Global", select "Communications & I/O" -
"EtherNet/IP".
Controlling the Controller
2
Click "Set" in "Data Settings".
The "EtherNet/IP Communication Data Structure"
screen appears.
3
Left-click "View List" in "Send-Data" and "Receive-
Data" to check the status of byte address and bit
address allocation for the items that are required
for controller control.
Receive-Data (PLC to Controller: OUT)
•Command request flag: Turns OFF→ON when a
command is executed (bit).
•Command Number: Sets the command No. of the
command to execute (double word).
•Command Parameter#: Sets the No. # argument
for the command (word). (Whether or not there
are arguments depends on the command.)
Send-Data (Controller to PLC: IN)
•Command complete flag: Turns ON when the
command process is completed (bit).
•Command error flag: Turns OFF when the
command process is completed, and ON when
a failure occurs (bit).
•Command ready flag: Turns ON when ready to
receive the command process (bit).
•Command Result: Sets the command execution
results (0: Success,
(double word).
•Command Data#: Sets the command No. #
response data (word). (Whether or not there is
response data depends on the command.)
4
Click "OK".
The changed settings are saved.