Command execution procedure example – KEYENCE CV-X Series User Manual
Page 11
KEYENCE CORPORATION. Vision System Division
‐ 11 ‐
www.keyence.com
✎
Command Execution Procedure Example
Save Settings (SS)
Here is an example of a command execution procedure. This section shows an example of executing the SS (Save Settings)
command which does not use a command parameter. The screens with
blue frames
show when the "Registration monitor"
function of KV STUDIO is used for confirmation.
Check the SS (Save Settings) command operation.
1. Enter "12", the SS command No., in the device
corresponding to the PLC Command Number (W0F4
in this example).
2. Enter "1" in the device corresponding to the PLC
Command request flag (B060 in this example).
3. The command is executed.
4.Check if the values of the devices corresponding to
the PLC Command complete flag and Command
result (B00 and W04 respectively in this example)
have changed.
When the command is successful: CV‐X writes "1" into Command complete
flag, and "0" into Command result.
When the command fails: CV‐X writes "1" into Command complete flag, and
an error code into Command result.