Select "Transfer to PLC" from the

"Monitor/Simulator" menu in KV STUDIO.

12

Restart both the CV-X100 Series and the KV Series.

When the connection is successful, the LINK LED

(green) will start flashing on the KV Series Ethernet

port.

Successful connection can also be confirmed by

selecting "Communications & I/O" ‐ "EtherNet/IP" in

"Global" on the CV‐X100 Series, and checking the

"Cyclic Communication Status".

If the LINK LED on the KV Series Ethernet port stays lit

(does not flash) or does not light

The EtherNet/IP may not be set up correctly, the cables may

not be connected correctly, or the CV‐X100 Series may not

be started up. Check the connection equipment (if a

crossover cable is being used as a LAN cable when

connected directly, if the HUB is working, etc.)