1. Before Connecting EtherNet/IP

(EtherNet/IP)

[Keyence KV Series]

2

Change the Ethernet settings and then left-click
"OK".

1

From "Global", select "Communications & I/O" -
"Network".

3

From "Global", select "Communications & I/O" -
"EtherNet/IP".

4

Change the EtherNet/IP settings and then left-click
"OK".

1. Checking the Global Settings of the CV-X100 Series

In this section, the set values below will be configured
as an example (change the settings according to the
target device).

IP Address: 192.168.0.10
Subnet Mask: 255.255.255.0

In this section, the set values below will be
configured as an example (change the settings
according to the target device).

Enable EtherNet/IP: Check this box.
Data Size: 496 bytes
Data Configurations: Set the desired data

allocations and allocation offset for the bit
address and byte address.

Decimal Point: Fixed‐point
Process Priority: Image First

5

Restart the controller.

This section describes how to establish EtherNet/IP.

[Important]
If it fails, establish a one-to-one connection between the
PLC and CV-X, and follow this manual to configure the
settings and check the operations.
Confirm that it operates properly, and change settings if
necessary.