Before connecting ethernet/ip – KEYENCE CV-X Series User Manual
Page 3
![background image](/manuals/658077/3/background.png)
365GB
KEYENCE CORPORATION. Vision System Division
‐ 3 ‐
www.keyence.com
1. Before Connecting EtherNet/IP
(EtherNet/IP)
[Keyence KV Series]
2
Change the Ethernet settings and then left-click
"OK".
1
From "Global", select "Communications & I/O" -
"Network".
3
From "Global", select "Communications & I/O" -
"EtherNet/IP".
4
Change the EtherNet/IP settings and then left-click
"OK".
1. Checking the Global Settings of the CV-X100 Series
In this section, the set values below will be configured
as an example (change the settings according to the
target device).
•IP Address: 192.168.0.10
•Subnet Mask: 255.255.255.0
In this section, the set values below will be
configured as an example (change the settings
according to the target device).
•Enable EtherNet/IP: Check this box.
•Data Size: 496 bytes
•Data Configurations: Set the desired data
allocations and allocation offset for the bit
address and byte address.
•Decimal Point: Fixed‐point
•Process Priority: Image First
5
Restart the controller.
This section describes how to establish EtherNet/IP.
[Important]
If it fails, establish a one-to-one connection between the
PLC and CV-X, and follow this manual to configure the
settings and check the operations.
Confirm that it operates properly, and change settings if
necessary.