1 sj-m series operations, Setup flow, Run mode – KEYENCE SJ-M200 User Manual
Page 8: Select mode, Setup mode, Sj-m series operations
7
2-2
Connection and Installation
AC adapter (SJ-U2)
Connect the AC adapter to the connector on the side of
the Controller Unit.
The AC adapter is available as an option.
3-1
SJ-M Series Operations
This section describes operation of the SJ-M Series.
Setup Flow
The setup flow for setting up the SJ-M Series is as follows.
■ When the SJ-M Series is turned ON for the first time
■ Moving between modes
Modes on the SJ-M series change as follows.
The unit starts up in the Run mode after the power is turned ON or after static elimination is
stopped.
Blink alternately at high speed
Blink
When the power is turned ON for the first time after purchase, the
SJ-M Series starts up at the “High temperature use setting” in the
Setup mode.
At this time, static elimination is not performed.
Select the appropriate settings using ,
and
press
.
Enter the Run mode, and start static elimination.
"High temperature use setting" (page 7)
Make the settings matched to the actual operating
environment. Incorrect settings may cause accidents
or malfunction.
Important
un mode>
elect mode>
on Balance Manual Adjustment mode>
etup mode>
One lit
Blink alternately
Blink alternately fast
Press for
a short time.
"BALANCE" lit
Hold down for
at least 1 second.
Hold down for
at least 1 second.
Hold down and
simultaneously
for at least 1 second.
Tip
3-1
SJ-M Series Operations
Run Mode
Regular static elimination operation is performed in the Run mode.
The following functions are available in the Run mode.
●
Ion monitor functions
"Ion Monitor Functions" (page 8)
●
Alarm output functions
"Alarm Output Functions" (page 9)
●
Confirmation of ion balance adjustment values
Select Mode
In this mode, select the setting items to change in the Setup mode
Setup Mode
In this mode, change the settings of the items selected in the Select mode.
A
B
C
E
D
Blink alternately
1
424
3
Operations in the Select mode
Press
for a short time:
Enters the Setup mode for the currently selected item.
Hold down
for at least 1 second:
Exits the Select mode, and returns to the Run mode.
:
Move the cursor up and down.
On the ion monitor, the currently selected items are lit (green), and the items
whose defaults have been changed are lit (red).
Items that satisfy both of these conditions blink red and green alternately.
The following describes each of the items in the Select mode:
:Ion level alarm, sensitivity setting
:Condition alarm, sensitivity setting
:High temperature use setting
:Tube head setting (I.C.C. ON/OFF)
:Initialization of settings
1
424
3
Blink alternately fast
Operations in the Setup mode
:Applies the setting at the selected conditions.
:Move the cursor up and down.
The following describes each of the items in the Setup mode:
1424
3
3-1
SJ-M Series Operations
■ Ion level alarm sensitivity setup
Sets the sensitivity at which the ion level alarm is output.
(1) High sensitivity (red):
Alarms are easily output.
(2) Medium sensitivity (orange):
(3) Low sensitivity (green):
Alarms are not easily output.
(4) No sensitivity (red):
No alarm output.
Default is “Low sensitivity.”
"Ion level alarm output function (ION LEVEL)" (page 9)
■ Condition alarm sensitivity setup
Sets the sensitivity at which the condition alarm is output.
(1) High sensitivity (red):
Alarms are easily output.
(2) Medium sensitivity (orange):
(3) Low sensitivity (green):
Alarms are not easily output.
(4) No sensitivity (red):
Alarms are easily output.
Default is “Low sensitivity.”
"Condition alarm output function (COND)" (page 9)
■ High temperature use setting
Make the settings matched to the operating environment.
(1):High temperature/nitrogen environment (red)
(2):Use in environments other than the above (green)
Default is (2).
1
2
3
4
Blink
Tip
1
2
3
4
Blink
Tip
1
2
Blink
High temperature use (+60°C to +80°C)
Tip
Make the settings matched to the actual operating
environment. Incorrect settings may cause
accidents or malfunction.
Important