Relationship between installation distance and wind speed according to air

flow rate

The relationship between wind speed and static elimination head installation distance varies according
to the air flow rate
Adjust the air supply flow rate referring to the following figures.

75

100 150 200 250 300 350

50

0

400mm

mm

50

25

0

-25

-50

-75

10m/s

2m/s

1m/s

75

200 300 400 500 600 700

100

0

1000mm

mm

50

25

0

-25

-50

-75

800 900

10m/s 5m/s

1m/s

2m/s

100

200 300 400 500 600 700

100

0

1500mm

mm

50

75

25

0

-25

-50

-75

-100

800 900 1000 1100 1200 1300 1400

10m/s

20m/s

5m/s

1m/s

1m/s

2m/s

2m/s

Air flow rate 250 Nl/min (pressure 0.5 MPa)

Air flow rate 20 Nl/min (pressure 0.01 MPa)

Air flow rate 60 Nl/min (pressure 0.08 MPa)

3-4

Other Functions

How to supply air

Supply air from the SJ-M010/020(G)'s Air Input Unit as
shown in the figure on the right.
Joints and tubes must be prepared separately.

Recommended joint

We recommend using a tube fitting (tube dia. 6mm, 8mm) made by PISCO for a joint to the Air Input
Unit.

Be sure to limit the tightening torque to 0.7 Nm. Tightening beyond this limit

may cause an accident or a malfunction.

Be sure to use the Air Input Unit. Using a different air supply may cause an

accident or a malfunction.

Rc1/8

Tube

Tube dia. 6 mm: PC6-01
Tube dia. 8 mm: PC8-01

CAUTION

3-4

Other Functions

I.C.C. Setting

The I.C.C. (Ion Current Control) can be turned on and off.
Turning off the I.C.C. allows the ion balance adjustment function to generate positive and negative ions
at a fixed ratio.