beautypg.com

Preface, Safety precautions – KEYENCE SJ-M200 User Manual

Page 2

background image

1

Preface

This document describes handling, method of operation and precautions when using the Compact
Spot-type Static Eliminator SJ-M 100/200 Series. Before you start to use the SJ-M 100/200 Series, be
sure to thoroughly read this document in order to make full use and safely use its functions.
Store this document in a safe place so that you can retrieve it whenever necessary.

Symbols

This manual uses the following symbols to alert you to important information.
Be sure to read this information.

Failure to follow these instructions may lead to death or serious injury.

Failure to follow these instructions may lead to injury.

Failure to follow these instructions may lead to product damage (product
malfunction, etc.).

Provides additional information on precautions and restrictions that must be
followed in operation.

Provides additional information on proper operation.

Indicates useful information or information that aids understanding of text descriptions.

Indicates a reference item or page to be referred to in this manual or a separate manual.

DANGER

WARNING

CAUTION

Important

Note

Tip

Safety Precautions

General Precautions

At startup and during operation, be sure to monitor the functions and

performance of the SJ-M Series.

We recommend that you take substantial safety measures to avoid any

damage in the event that a problem occurs.

Do not modify the SJ-M Series or use it in any way other than described in

the specifications. The functions and performance of products used or
modified in this way cannot be assured.

When the SJ-M Series is used in combination with other instruments,

functions and performance may be degraded, depending on operating
conditions and the surrounding environment. Use the SJ-M after fully
studying the effect of combined use with other instruments.

Do not use the SJ-M Series for the purpose of protecting the human body.

SJ-M Series Handling Precautions

The SJ-M Series is a high-voltage product that is not designed in an explosion-proof structure. Pay
attention to the following when using the SJ-M Series.

To prevent electric shock and to ensure accurate static elimination, be sure

to connect a Class D earth (maximum resistance of 100 Ohms).

The power cable supplied with the exclusive power supply (SJ-U2) is a 125 V

rated power cable. When connecting a power supply that exceeds this power
rating to the SJ-M Series, the user must prepare a power cable having
adequate voltage rating. If a power cable that does not meet the voltage
rating is used, this may cause electric shock, fire or malfunction.

Do not use this product in locations where there is the risk of ignition or

explosion from flammable solvents or dirt and dust.

High voltage is applied to this product. Prevent it from being splashed with

water, oil, or flammable solvents. Failure to do so may cause insulation
breakdown, which will result in electric shock or malfunction.

Do not bring your fingers, tools, wire or other metallic objects near this

product. Doing so may cause electric shock or malfunction.

Protect the area around the tip of the Static Elimination Head with silicon,

fluoro-resin or other highly ozone-resistant resin. Ozone that is generated
may cause the metal or resin on the SJ-M Series to rust, corrode or
deteriorate.
The ozone generated from this product may adversely affect the human
body. For this reason, do not use the SJ-M Series in closed spaces. Be sure
to use the SJ-M Series in a well-ventilated location. Also, do not bring your
face close to the Static Elimination Head. The ozone generated from this
product might be painful to your nose or throat.

Do not use this product in locations where sudden changes in temperature

or condensation are likely to occur.

Do not operate this product with wet hands. Doing so may cause electric

shock.

Before starting inspection or maintenance, be sure to turn the power OFF.

Failure to do so might result in electric shock or malfunction.

During maintenance, do not directly touch the electrode probe. Doing so may

cause personal injury.

Supply air according to the deratings indicated in the specifications. Use

without performing derating might result in electric shock or malfunction

If any malfunction is observed in this product, immediately turn it OFF, and

contact your nearest agent. You should never repair this product yourself.
Doing so may cause electric shock or malfunction.

CAUTION

WARNING

Do not touch the electrode probe with a tool or other hard object. Damage to

the electrode probe will prevent static elimination performance from being
fully demonstrated, and cause accidents or malfunction.

When this product is used for a long period of time, the electrode probe

become dirty due to the adhesion of dust and dirt. If the ion level alarm
indicator or condition alarm indicator lights, clean the electrode probe. If the
product is used with the electrode probe in a dirty or dusty state, the static
elimination performance can no longer be fully demonstrated, resulting in
accidents or malfunction. We recommend periodically cleaning the
electrode probe (as a guideline, once every two weeks in a regular operating
environment though this depends on the installation conditions).

Do not drop or subject this product to shock. Doing so might result in

accident or malfunction.

Use this product for static elimination only. Do not use it for other purposes.
When installing the SJ-M Series, observe the minimum bending radius of all

provided cables. Also, do not install the SJ-M with the cables deformed by
staples or other objects. Doing so might cause the SJ-M to malfunction.

Power Supply Precautions

Use a DC power supply with rated 24 V output.
Noise applied to the power supply may cause this product to malfunction. If

this happens, install an insulated transformer.

When using a switching regulator, be sure to connect a Class D earth to the

Frame Ground terminal.

Grounding Precautions

To ensure safety and appropriate static elimination, be sure to ground this

product.

Be sure to connect a Class D earth (maximum resistance of 100 Ohms)

Air Purge Function Precautions

Be sure to use air of pressure 0.001 MPa to 0.5 MPa. Use outside of the rated

air pressure range might result in accidents or malfunction.

Be sure to supply clean or dry air of temperature –20°C or more through a

filter of mesh size about 0.01μm. Moisture or oil contained in the air or
nitrogen may cause discharge inside the Static Elimination Head, which
may result in accidents or malfunction.

CAUTION

CAUTION

CAUTION

CAUTION

SJ-M Series Warning label

A WARNING label is affixed on the SJ-M Series to ensure safety. Read the description on this
WARNING label to ensure correct use of the SJ-M Series.

Installation Precautions

Avoid installing the SJ-M Series in the following locations as this may cause
accidents.
Locations directly subject to vibration and shock
Locations subject to ambient temperature outside of the 0°C to +40°C range

(excluding the High-voltage Cable Unit)

Locations subject to ambient temperature outside of the 0°C to +80°C range

(High-voltage Cable Unit)

Locations subject to ambient humidity outside of the 35 to 65%RH range

(condensation not allowed) (excluding the High-voltage Cable Unit)

Locations subject to ambient humidity outside of the derating range

(condensation not allowed) indicated in the specifications (High-voltage
Cable Unit)

Locations subject to sudden changes in temperature
Locations subject directly to blasts from air conditioners
Locations subject to volatile or flammable substance, solvents or corrosive

gases

Locations subject to large amounts of dirt, and dust, salt, iron and oil smoke
Locations that may be splashed with water, oil or chemical mist
Locations where strong magnetic and electrical fields are generated

About Warm-up

After turning the SJ-M Series ON, leave it for about 20 minutes to allow the ion
balance to stabilize.

WARNING labels in Japanese, German, French, Italian and Chinese (Simplified) are provided.
Use them as necessary.

CAUTION

Note

This manual is related to the following products: