beautypg.com

Using each function dip switches, Response speed selection function – KEYENCE LK-3100 User Manual

Page 16

background image

16

Response speed selection function

Set DIP switch 3 to select whether to output every measured value or
the average of 8 measured values (moving average).

LOW:
Outputs the value of the average of 8 measured values. Offers more
stable detection when the luster of the target varies greatly.

HIGH:
Outputs every measured value. Offers high-speed response when the
target vibrates or moves quickly.

USING EACH FUNCTION DIP SWITCHES

Sampling cycle

128

µs

256

µs

512

µs

2048

µs

LOW

Approx. 1 ms Approx. 2.0 ms Approx. 4.0 ms Approx. 17 ms

HIGH

Approx. 0.1 ms Approx. 0.2 ms Approx. 0.5 ms Approx. 2 ms

Example: To cancel the influence by surface roughness, LOW is

recommended.

Example: To detect abrupt changes such as height differences,

HIGH is recommended.

LOW
HIGH

3

2

1

Average
response
time

Analog
output

Analog
output

• DIP switch (HIGH)

• DIP switch (LOW)

Analog
output

Analog
output

• DIP switch (HIGH)

• DIP switch (LOW)