Setup functions, Lase r, Re s a l – KEYENCE IB Series User Manual
Page 2: Blinking slow misaligned, Blinking fast aligned, Hi] lights up. low tolerance value [lo] lights up, Received light, High tolerance value
2
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
GO
HOLD
CALC
CHECK
Setup Functions
Registering the reference light
To measure the target stable, the amount of received light must be
registered first.
1. Press both the left/right arrow button for at least 2 seconds, to show
the received light level.
2. Confirm that the laser transmitted from the transmitter is reaching
the receiver properly, and the “Laser emission warning indicator” is
blinking fast.
Laser emission
warning LED
Explanation
Image
Off
Not received
Blinking slow
Misaligned
Blinking fast
Aligned
3. Press [MODE] and [SET] for at least 2 seconds.
The reference light will be registered.
Set the R.V. value to the Shift target value
1. Press the left/right arrow buttons until
the sub display shows the Shift target
value.
2. Press the up/down arrow button to change the Shift target value.
3. Press the [ZERO SHIFT] button.
4. The current R.V. value would be set to the Shift target value.
Set the HIGH and LO tolerance.
1. Press the left/right arrow buttons until the sub display shows the
HIGH/LOW limit setting value.
2. Input the HIGH or LO tolerance by pressing the up/down arrow
buttons.
3. The HIGH and LOW tolerance will be set.
Setting the Key Lock
1. Press the [MODE] and the up (or down) arrow button for at least 2
seconds.
2. The Key Lock display would appear.
Canceling the Key Lock
1. When the Key Lock is set, press the MODE and the up (or down)
arrow button for at least 2 seconds.
2. The Key Lock would be cancelled.
Initializing the sensor
1. Press the SET button 5 times while
pressing the MODE button. The main
display will show “rESET”.
2. Select “YES” by pressing the up/down
arrow button, and press the [MODE]
button. The main display will show “out”.
3. Select the output polarity from “NPN”
and “PNP” by pressing the up/down
arrow button, and press the [MODE]
button. The main display will show
“AnLG”.
4. Select the analog output from “oFF”,
“0-5V”, “-5-5V”, “1-5V” and “4-20mA” by
pressing the up/down arrow button, and
press the [MODE] button. The sensor
will be initialized.
Changing the bank (program)
1. Press the up/down arrow button while pressing the [MODE] button.
2. The bank (program) would be switched to another one. Each bank
(program) will have an own HIGH limit setting value/LOW limit
setting value/Shift target value.
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
S HIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
GO
HOLD
C ALC
CHECK
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
GO
HOLD
CALC
CHECK
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
GO
HOLD
CALC
CHECK
LASE
R
R
. o N L
A I R E S
R
E
S
A
L
T
R
E
S
A
L
T
R
. o N
L A I R
E S
R
. o N L
A I R E
S
R
E
S
A
L
T
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
GO
HOLD
CALC
CHECK
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
GO
HOLD
CALC
CHECK
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
GO
HOLD
CALC
CHECK
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
GO
HOLD
CALC
CHECK
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
GO
HOLD
CALC
CHECK
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
GO
HOLD
CALC
CHECK
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
GO
HOLD
CALC
CHECK
Beam axis is misaligned.
Beam axis is aligned.
Transmitter
Reciever
Reciever
Transmitter
Laser emission waining indicator
Off
Blink (slow)
Blink (fast)
Registration completed
Shift target value
[SHIFT]
lights up.
HIGH tolerance value
[HI]
lights up.
LOW tolerance value
[LO]
lights up.
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
GO
HOLD
CALC
CHECK
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
GO
HOLD
CALC
CHECK
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
GO
HOLD
CALC
CHECK
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
GO
HOLD
CALC
CHECK
Performing the initial reset
Output polarity
Analog output
Press ▼ while
holding down the
[MODE] button.
Press ▼ while holding
down the [MODE] button.
Press ▼ while holding
down the [MODE] button.
Press ▼ while holding
down the [MODE] button.
< While Bank 1 is selected>
< While Bank 2 is selected>
< While Bank 3 is selected>
BANK 0 lights
BANK 1 lights
BANK 2 lights
BANK 3 lights
Received light