SETTING THE SENSITIVITY
(AUTOMATIC CALIBRATION)

Select the sensitivity setting procedure according to the target
condition.
When the setting is completed, the setting value flashes twice.

For sensitivity adjustment using a moving target

Fully-automatic Calibration

1. Pass a target through the

optical axis while pressing
the SET button.

2. Confirm that the calibration

indicator (orange LED)
flashes.

3. Release the SET button.

The setting value is adjusted
to the midpoint of the differ-
ence between the maximum
and minimum values of the
received light intensity.

If the fully-automatic calibration does not work properly, try the two-
point calibration.

For sensitivity adjustment using a stationary target

Two-point Calibration

1. With no target in place,

press the SET button and
release it. (The orange LED
lights.)

2. Position a target in place.

Press the SET button again
and release it.

The setting value is adjusted
to the midpoint of the differ-
ence in the received light
intensity when the target is
absent and present.

For target positioning

Positioning Calibration

1. With no target, press the

SET button and release it.
(The orange LED lights.)

2. Place a target in the position

where it is to be stopped.

3. Press the SET button for 3

seconds or more until the
calibration indicator (orange
LED) flashes. Release the
SET button.

For maximum sensitivity

Maximum sensitivity setting

1. Under the conditions on the

left, press the SET button
for 3 seconds or more.

2. Confirm that the calibration

indicator (orange LED)
flashes.

3. Release the SET button.

If the detecting distance is insufficient, try the two-point calibration.

Received light intensity

SET

Setting
value

Time

3 seconds
minimum.

Max.

Received light intensity

SET

1

2

Setting
value

Time

SET

1

2

3 seconds
minimum.

The setting value is adjusted to
turn on the sensor when the target
comes to the place where it should
be stopped.

Reflective type

With no target

Thrubeam type

With target

When the reflective type is used to
detect a target with some objects in
the background, the sensitivity is
set to the maximum value at which
the background objects are not
detected.

CHANGING THE SETTING VALUE
(MANUAL CALIBRATION)

Use the

button.

Received light intensity display

Press

or

once. The setting value flashes.

Change the setting value by pressing

or

while the value is

flashing.

UP DOWN

Current
value display

Press

or

once.

Flashing
display

Wait for 2 seconds.

The current value appears after 2 seconds.*

Excess gain display

Press

or

once. The setting value flashes.

Change the setting value by pressing

or

while the value is

flashing.

Press

to increase sensitivity.

(The setting value
decreases.)

Press

to decrease sensitivity.

(The setting value
increases.)

Press

to increase sensitivity.

Press

to decrease sensitivity.

The current value appears after 2 seconds.*

Note: If the SET button is pressed by accident while the sensitivity is
being manually changed, the automatic sensitivity setting will start
(The calibration indicator lights.). The sensitivity cannot be changed
until the automatic sensitivity setting is completed (The calibration
indicator goes off.).

* Do not press any buttons other than the manual button while the

setting value is flashing. Otherwise, the value cannot be changed
properly.

• When the sensitivity difference is insufficient
If the sensitivity has no allowance, “- - - -” flashes immediately after the
completion of the automatic calibration.

Note: Sensitivity is set and entered even when the sensitivity differ-
ence is insufficient. Be sure to confirm that the detection is properly
performed.

• Locking the operation button
Hold down

and [MODE] or

and [MODE] simultaneously for 3

seconds or more to lock the operation buttons. When “Loc” is dis-
played in flashing letters, the buttons are locked.

To unlock the operation buttons, repeat the procedure above. When
“vnL” is displayed in flashing letters, the buttons are unlocked.
Even when the operation buttons are locked, you can change the
display data or output method, or display the setting value.