beautypg.com

Sensor amplifier – KEYENCE PS-N10 Series User Manual

Page 11

background image

11

„

Sensor Amplifier

*1 Counted as one output when units are added to NU series communication units.
*2 Input time is 25 ms (ON)/25 ms (OFF) only when an external tuning input is selected.
*3 The operating ambient temperature varies as shown below when units are added. For expansion, be sure to mount the units on the DIN rail (metallic plate) and
prevent the output current for each unit from exceeding 20 mA.
- 20

ºC to + 55ºC for 1 or 2 units added, - 20ºC to + 50ºC for 3 to 10 units added, - 20ºC to + 45ºC for 11 to 16 units added

*4 When connecting nine or more expansion units, ensure that the power voltage is 20 V or more.
*5 The maximum power consumption including load is 29.3 W.
*6 Use with the over current protection device which is rated 30 V or more and not more than 1 A.

Cable / Connector

Cable

M8 Connector

0-line

Main unit / Expansion unit

Main unit

Expansion unit

Main unit

Expansion unit

Expansion unit

Model

NPN

PS-N11N

PS-N12N

PS-N11CN

PS-N12CN

PS-N10

PNP

PS-N11P

PS-N12P

PS-N11CP

PS-N12CP

Control output

1 output

1 output

1 output

1 output

N/A

*1

External input

1 input

N/A

1 input

1 input

N/A

Response time

500

μs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA)

Output operation

Light-ON/Dark-ON

Timer function

Timer OFF, OFF delay, ON delay, One-shot

Timer variable (1 ms to 9999 ms) Maximum error to setting value is μ10 % or less

Control output

NPN output

NPN open collector 30 V, Max: 100 mA or less (for standalone operation)/20 mA or less (for expansion)

Residual voltage 1 V or less (Output current: 10 mA or less)/2 V or less (Output current: 10 to 100 mA)

PNP output

PNP open collector 30 V, Max: 100 mA or less (standalone operation)/20 mA or less (for expansion)

Residual voltage 1.2 V or less (Output current: 10 mA or less)/2.2 V or less (Output current: 10 to 100 mA)

External input

No-voltage input (with/without contact), Input time 2 ms (ON)/20 ms (OFF) or more

*2

Expansion units

Up to 16 units (a total of 17 units connected)

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, and output wiring error

Number of interference prevention units

TURBO/SUPER/ULTRA/MEGA: 4 (These numbers double when "Double" is selected.)

Rated

Power voltage

*4

24 VDC (operating voltage 10-30 VDC (including ripple)), ripple (P-P) 10 % or less, Class 2 or LPS

NPN

*5

Normal: 810 mW or less (28 mA or less at 24 and 30 V, 34 mA or less at 12 V)

Eco on: 700 mW or less (24 mA or less at 24 and 30 V, 27 mA or less at 12 V)

Eco full: 490 mW or less (17 mA or less at 24 and 30 V, 20 mA or less at 12 V)

PNP

*5

Normal: 860 mW or less (30 mA or less at 24 and 30 V, 35 mA or less at 12 V)

Eco on: 750 mW or less (26 mA or less at 24 and 30 V, 28 mA or less at 12 V)

Eco full: 540 mW or less (19 mA or less at 24 and 30 V, 21 mA or less at 12 V)

Environmental

resistance

Operating ambient

temperature

- 20°

ºC to + 55°ºC (no freezing)

*3

Operating ambient

humidity

35 to 85 % RH (no condensation)

Vibration resistance

10 to 55 Hz, compound amplitude 1.5 mm, 2 hours for each of X, Y, Z axes

Shock resistance

500 m/s

2

, 3 times for each of X, Y, Z axes

Material

Housing

Amplifier body and dust cover material: Polycarbonate

Cable

PVC

Housing dimensions

H 32.6 mm x W 9.8 mm x L 78.7 mm

Weight

Approx. 75 g

Approx. 65 g

Approx. 20 g

Approx. 20 g

Approx. 20 g