Sensor amplifier – KEYENCE PS-N10 Series User Manual
Page 11

11
Sensor Amplifier
*1 Counted as one output when units are added to NU series communication units.
*2 Input time is 25 ms (ON)/25 ms (OFF) only when an external tuning input is selected.
*3 The operating ambient temperature varies as shown below when units are added. For expansion, be sure to mount the units on the DIN rail (metallic plate) and
prevent the output current for each unit from exceeding 20 mA.
- 20
ºC to + 55ºC for 1 or 2 units added, - 20ºC to + 50ºC for 3 to 10 units added, - 20ºC to + 45ºC for 11 to 16 units added
*4 When connecting nine or more expansion units, ensure that the power voltage is 20 V or more.
*5 The maximum power consumption including load is 29.3 W.
*6 Use with the over current protection device which is rated 30 V or more and not more than 1 A.
Cable / Connector
Cable
M8 Connector
0-line
Main unit / Expansion unit
Main unit
Expansion unit
Main unit
Expansion unit
Expansion unit
Model
NPN
PS-N11N
PS-N12N
PS-N11CN
PS-N12CN
PS-N10
PNP
PS-N11P
PS-N12P
PS-N11CP
PS-N12CP
Control output
1 output
1 output
1 output
1 output
N/A
*1
External input
1 input
N/A
1 input
1 input
N/A
Response time
500
μs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA)
Output operation
Light-ON/Dark-ON
Timer function
Timer OFF, OFF delay, ON delay, One-shot
Timer variable (1 ms to 9999 ms) Maximum error to setting value is μ10 % or less
Control output
NPN output
NPN open collector 30 V, Max: 100 mA or less (for standalone operation)/20 mA or less (for expansion)
Residual voltage 1 V or less (Output current: 10 mA or less)/2 V or less (Output current: 10 to 100 mA)
PNP output
PNP open collector 30 V, Max: 100 mA or less (standalone operation)/20 mA or less (for expansion)
Residual voltage 1.2 V or less (Output current: 10 mA or less)/2.2 V or less (Output current: 10 to 100 mA)
External input
No-voltage input (with/without contact), Input time 2 ms (ON)/20 ms (OFF) or more
*2
Expansion units
Up to 16 units (a total of 17 units connected)
Protection circuit
Protection against reverse power connection, output overcurrent, output surge, and output wiring error
Number of interference prevention units
TURBO/SUPER/ULTRA/MEGA: 4 (These numbers double when "Double" is selected.)
Rated
Power voltage
*4
24 VDC (operating voltage 10-30 VDC (including ripple)), ripple (P-P) 10 % or less, Class 2 or LPS
NPN
*5
Normal: 810 mW or less (28 mA or less at 24 and 30 V, 34 mA or less at 12 V)
Eco on: 700 mW or less (24 mA or less at 24 and 30 V, 27 mA or less at 12 V)
Eco full: 490 mW or less (17 mA or less at 24 and 30 V, 20 mA or less at 12 V)
PNP
*5
Normal: 860 mW or less (30 mA or less at 24 and 30 V, 35 mA or less at 12 V)
Eco on: 750 mW or less (26 mA or less at 24 and 30 V, 28 mA or less at 12 V)
Eco full: 540 mW or less (19 mA or less at 24 and 30 V, 21 mA or less at 12 V)
Environmental
resistance
Operating ambient
temperature
- 20°
ºC to + 55°ºC (no freezing)
*3
Operating ambient
humidity
35 to 85 % RH (no condensation)
Vibration resistance
10 to 55 Hz, compound amplitude 1.5 mm, 2 hours for each of X, Y, Z axes
Shock resistance
500 m/s
2
, 3 times for each of X, Y, Z axes
Material
Housing
Amplifier body and dust cover material: Polycarbonate
Cable
PVC
Housing dimensions
H 32.6 mm x W 9.8 mm x L 78.7 mm
Weight
Approx. 75 g
Approx. 65 g
Approx. 20 g
Approx. 20 g
Approx. 20 g