Troubleshooting

Problem Table

The following table describes some symptoms with possible causes and solutions.

Symptom

No power up, nothing on display

If any power reaches the control panel, the display driver turns on some random segments. Since we are not seeing
this we will assume that no power is reaching the scale circuitry.
Some possible causes:
Defective wiring harness: Inspect for damaged wiring.
Defective battery pack: Measure battery voltage, charge or repair as needed.
Defective ON switch: Bridge switch to see if unit turns on.
Defective circuitry: Replace control panel.
The power supply may be delivering power, but it might be eaten up with a defective circuit board or cable. Unplug
the load cell cable. If the scale turns on at this point, a load cell lead is shorted. Turn the power off and try each cell
lead in turn. If it is the load cell cable, look for a crushed cable.
Symptom

Power up to random display

We know that some power is reaching the display driver circuit, but the control panel is not working correctly. Test
for low battery voltage. Inspect for visible damage. If this fails replace the control panel.
Symptom

Scale shuts off

If the scale turns off IMMEDIATELY after you take your finger off the off button, you may have very low batteries. If
this is not the cause replace the control panel.
Symptom

"Locks up"

The scale may be mis-programmed. This can be corrected by restoring the correct control parameters. If the
Average Rate setting is very high, an active load may not update the display quickly which may be interpreted as a
lock up
Symptom

No backlight

Cover the light sensor window. If the light does not turn on, replace the control panel. Please note that the light is
not visible in bright sunlight.
Symptom

Slow operation

This may be caused by a programmed change in the filter setting. There is a tradeoff between speed and stability of
the display reading. This can be tuned by changing the “Average Rate” setting.
Symptom

Low battery indicator won't turn off

It is possible that the output from the batteries is really low. Look at the cells and charger circuit for these problems.
If the battery voltage is correct then you will need to replace the control panel.
Symptom

Jumpy or drifty weights

This can usually be traced to contamination on circuit boards or a bad load cell. This can also be caused by a rapid
change in temperature. The scales need at least one-hour acclimation time for each 10 degrees Fahrenheit of
temperature change. Another possibility is powerful radio interference.
Symptom

No response to one or more keys

The switch may be defective. The control panel may be defective. The zero key does not function while the scale is
in motion, this is not a defect. Also, the scale may be programmed to ignore the zero key if there is more than a
certain amount of weight on the platform.
Symptom

"Bad" weights

First, check weighing technique. Are there air currents around the vehicle being weighed? Are the operators using
dummy blocks on the un-weighed wheels? (NOT a recommended technique) Are the scales being used on level
ground? Is the scale set on the wrong units settings? Is a new operator using the scales? If on a calibration press,
are you using weight distribution blocks and rubber scales? Is the reference scale correct? Assuming all this, is the
scale spanned correctly? If the reading is exactly 3/4 of the expected value, one of the cells leads may not be
providing signal. This would probably be in the load cell or control circuit. The interconnecting wiring or cables may
be pinched, cut or crushed.
Symptom

Batteries won't charge

Check for bad batteries. The charger circuit could be out. Check for bad connections or a defective charging cable.
Look at the power source, whether it's a plug-in transformer, transport cart, or automotive ignition. Remove the
battery cap with the scale plugged into the charger. If the scale turns on then the charger is working.

Caution: Changing any circuit board or load cell will affect the calibration. The calibration should
be verified after any repairs.