Totalizing Setup

This section covers configuring a scale set for either self-totalizing or connection to a PC/PDA
for advanced display features. For accumulating multiple weights on a scale or scale set, see
the “Using Accumulated Total” section. In ‘self-totalizing’ mode, the LOCAL/TOTAL button
works to switch between weight on that particular scale (LOCAL) and the total weight of
connected scales (TOTAL). If the system is not setup correctly, the “error icon” and message
“t0t

t0t

t0t

t0t “will be displayed when trying to view the total weight.


1. To enter into totalizing setup: Simultaneously press the LOCAL/TOTAL and ZERO buttons.
2. Message “SCid

SCid

SCid

SCid” will be displayed. Press PRINT/ACCUMULATE button. A number will be

displayed with 3 dashes following it. This is the scale number (ID). Use the LOCAL/TOTAL
button to increment and the ZERO button decrement the number. When the desired
number is displayed, press the PRINT/ACCUMULATE.



3. Message “SCLS

SCLS

SCLS

SCLS” will be displayed. Press the PRINT/ACCUMULATE button. The display

will show three dashes and then a number. This number is the total number of scales in
the system. Use the LOCAL/TOTAL button to increment and the ZERO button decrement
the number. When the desired number is displayed, press the PRINT/ACCUMULATE
button. The maximum number of scales is 32.




4. If the scale# is ‘1’, the display will ask if the scale is the “HOSt

HOSt

HOSt

HOSt”. Press the

PRINT/ACCUMULATE button. Use the LOCAL/TOTAL or the ZERO button to toggle the
display “Yes

Yes

Yes

Yes” or “no

no

no

no”. A ‘Host’ controls the scale network, and this setting should be set to

“yes” if the scale network consists of scales only. If your system uses an external device
such as a PDA or PC to view the weights, this setting should be set to “no” since the
external host controls the network. Press the PRINT/ACCUMULATE button to save the
setting.

Example 1 of correct scale settings: 4 pad system with PDA or PC:

Scale ID Number of Scales *Host setting

Scale #1:

[01---

01---

01---

01---] [---

---

---

---04

04

04

04]

[ no

no

no

no ]

Scale #2:

[0

00

02

22

2---

---

---

---] [---

---

---

---04

04

04

04]

Scale #3:

[0

00

03

33

3---

---

---

---] [---

---

---

---04

04

04

04]

Scale #4:

[0

00

04

44

4---

---

---

---] [---

---

---

---04

04

04

04]


---04

---04

---04

---04

total # of scales

(only displayed on scale #1)

01---

01---

01---

01---

scale ID#