Page 36

PT300 Users manual
Rev G, Feb 2011
Page 36 of 44
Span Calibration
Note: The numbering from the “setting the calibration parameters” continues here.
11. The display will show “SAvE
SAvE
SAvE
SAvE” for about 1 second and advance to show “CAP
CAP
CAP
CAP”. Press the
PRINT/ ACCUMULATE button. The display will show the current capacity setting with the far
right number flashing. Use the LOCAL/TOTAL button the advance the number and the ZERO
button the move the number flashing to the left. Enter the capacity of the scale and press the
PRINT/ACCUMULATE button when the scale capacity is displayed.
12. The display shows “LL-00
LL-00
LL-00
LL-00”. With no weight applied to the scale press the PRINT/
ACCUMULATE button.
13. The display shows “HH-01
HH-01
HH-01
HH-01”. Press the PRINT/ACCUMULATE button. The display will show
“00000
00000
00000
00000” with the far right number flashing. Use the LOCAL/TOTAL button to advance the
number and the ZERO button to move the number flashing to the left. Enter the value of the
first load and press the PRINT/ACCUMULATE button when the value of the first load is
displayed.
14. The display shows “LL-01
LL-01
LL-01
LL-01”. Apply the first load to the scale. With the first load applied to the
scale press PRINT/ACCUMULATE button.
15. The display shows “HH-02
HH-02
HH-02
HH-02”. Press the PRINT/ACCUMULATE button. The display will show
“00000
00000
00000
00000” with the far right number flashing. Use the LOCAL/TOTAL button to advance the
number and the ZERO button to move the number flashing to the left. Enter the value of the
second load and press the PRINT/ACCUMULATE button when the value of the second load is
displayed.
16. The display shows “LL-02
LL-02
LL-02
LL-02”. Apply the second load to the scale. With the second load applied
to the scale press PRINT/ACCUMULATE button.
17. The display shows “HH-03
HH-03
HH-03
HH-03”. Press the PRINT/ACCUMULATE button. The display will show
“00000
00000
00000
00000” with the far right number flashing. Use the LOCAL/TOTAL button to advance the
number and the ZERO button to move the number flashing to the left. Enter the value of the
third load and press the PRINT/ACCUMULATE button when the value of the third load is
displayed.
18. The display shows “LL-03
LL-03
LL-03
LL-03”. Apply the third load to the scale. With the third load applied to
the scale press PRINT/ACCUMULATE button.
19. The display shows “HH-04
HH-04
HH-04
HH-04”. Press the PRINT/ACCUMULATE button. The display will show
“00000
00000
00000
00000” with the far right number flashing. Use the LOCAL/TOTAL button to advance the
number and the ZERO button to move the number flashing to the left. Enter the value of the
forth load and press the PRINT/ACCUMULATE button when the value of the forth load is
displayed.