Page 37
PT300 Users manual
Rev G, Feb 2011
Page 37 of 44
20. The display shows “LL-04
LL-04
LL-04
LL-04”. Apply the forth load to the scale. With the forth load applied to
the scale press PRINT/ACCUMULATE button.
Repeat step 12 and 13 for each additional “HH-05
HH-05
HH-05
HH-05” – “HH10
HH10
HH10
HH10” and “LL-05
LL-05
LL-05
LL-05”- “HH10
HH10
HH10
HH10” combination. If
the scale is turned off at any time the calibration data acquired to that point will be retained. After
the PRINT/ACCUMULATE button is pressed after “LL-10”, the display will return to normal
weighing.
Finished
Following calibration, replace the strap to shorting pins 2 and 3 (RUN); replace the assembly and
reattach the assembly with the screws. This will ensure that the calibration information of the
scale is protected from being changed.
Note: Care must be taken to ensure the wire harness is seated properly to prevent it
from being pinched between the display assembly and the scale casing.