beautypg.com

Finished – Holtgreven Truck Scale Resources User Manual

Page 37

background image

PT300 Users manual

Rev G, Feb 2011

Page 37 of 44

20. The display shows “LL-04

LL-04

LL-04

LL-04”. Apply the forth load to the scale. With the forth load applied to

the scale press PRINT/ACCUMULATE button.


Repeat step 12 and 13 for each additional “HH-05

HH-05

HH-05

HH-05” – “HH10

HH10

HH10

HH10” and “LL-05

LL-05

LL-05

LL-05”- “HH10

HH10

HH10

HH10” combination. If

the scale is turned off at any time the calibration data acquired to that point will be retained. After
the PRINT/ACCUMULATE button is pressed after “LL-10”, the display will return to normal
weighing.

Finished


Following calibration, replace the strap to shorting pins 2 and 3 (RUN); replace the assembly and
reattach the assembly with the screws. This will ensure that the calibration information of the
scale is protected from being changed.

Note: Care must be taken to ensure the wire harness is seated properly to prevent it
from being pinched between the display assembly and the scale casing.