PT300 Users manual

Rev G, Feb 2011

Page 22 of 44

function, meaning the scale will never shut itself off. Use the LOCAL/TOTAL button the
advance the number and the ZERO button to move the number flashing to the left. When
the display shows the desired number, press the PRINT/ACCUMULATE button.

8. The display will show “Prt t

Prt t

Prt t

Prt t”. Press the PRINT/ACCUMULATE button. The flashing digit

shows the current setting. The number enables the scales different print modes. (0 for on-
demand, 1 for continuous, 2 for accumulating total axle format, and 3 for accumulating total
standard format) Use the LOCAL/TOTAL button to increment and the ZERO button to
decrement the number. When the display shows the desired number, press the
PRINT/ACCUMULATE button.

9. The display will show “PbAUd

PbAUd

PbAUd

PbAUd”. Press the PRINT/ACCUMULATE button. The flashing

display shows the current setting of the printer baud rate. The baud rates available are:
1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200. Use the LOCAL/TOTAL
button or the ZERO button to toggle through the available rates. When the display shows
the desired number, press the PRINT/ACCUMULATE button.

10. The display will show “UnitS

UnitS

UnitS

UnitS”. Press the PRINT/ACCUMULATE button. The lb or the kg

icon will flash in the upper left of the display. This will set the scale to measure pounds (lb)
or kilograms (kg). Use the LOCAL/TOTAL button or the ZERO button to toggle between
the settings. When the desired icon is flashing, press the PRINT/ACCUMULATE button.

11. The display will show “Proto

Proto

Proto

Proto”. Press the PRINT/ACCUMULATE button. The flashing

display shows the current setting. There are 4 protocol settings for the scale, Standard
(“StAnd

StAnd

StAnd

StAnd”), Low Power (“Lo Pr

Lo Pr

Lo Pr

Lo Pr”), Current Loop (“C

CC

C.L00P

L00P

L00P

L00P”), or “None

None

None

None”

.

Standard is a setting for use in specific wireless and wired scale networks. Low Power
will significantly improve the wireless battery life for all non-‘host’ scales (maximum number
of scales in this mode is 32).

Current Loop is used when connecting to older legacy PT300 scales. The legacy cables
(part #’s 100488, 100489, or 100490) must be used when in this communication mode.
See section titled “Totalizing/Printing in Current Loop Mode” for more information.

When scales are not part of a totalizing network, battery life will be improved if “nonE

nonE

nonE

nonE” is

chosen. Use the LOCAL/TOTAL button or the ZERO button to cycle through the settings.
When the desired protocol is flashing, press the PRINT/ ACCUMULATE button.

12. The display will show “i

ii

i.bAud

bAud

bAud

bAud”. Press the PRINT/ACCUMULATE button. The display will

show the current setting flashing. This is the setting of the interface baud rate. There are
two settings available, 9600 and 115200. Use the LOCAL/TOTAL button or the ZERO
button to toggle between the settings. When the desired baud rate is flashing, press the
PRINT/ ACCUMULATE button.

13. The display will show “rAdio

rAdio

rAdio

rAdio”. Press the PRINT/ACCUMULATE button. The display will

show the current setting flashing. This is the radio enable status and is either on or off.
Use the LOCAL/TOTAL button or the ZERO button to toggle between the settings. When
the desired status is flashing, press the PRINT/ ACCUMULATE button. If you select “no”
the scale will skip the rest of the settings and return to normal weighing.