beautypg.com

Weighing system tests - optional, Weighing system tests - optional -4 – Hardy WS100 Configuration Software User Manual

Page 9

background image

HI WS100 CONFIGURATION SOFTWARE

1-4

DVM - (Digital Volt Meter) If you have a “J
Box”, the voltage outputs from the individ-
ual loadcells can be read. If you do not have
a “J Box” the voltage is a combined voltage
output from all loadcells in the system.

System Test - If you have a “J Box” you
can read the weight being read on individual
load cells and the internal reference.

Weighing System
Tests - Optional

Requires the HI 215IT Junction Box. This test is used
to diagnose drifting or unstable weight reading prob-
lems. The Weighing System Test does the following:

1.

Disconnects the controller and engages an inter-
nal reference signal to see if the problem is within
the instrument.

1.

Disconnects the load sensors and engages an
internal (in the junction box) reference signal to
see if the cable between the instrument and the
Junction Box is causing the problem.

2.

Reads the weight of each load sensor to see if the
load sensor might be causing the problem.

The ability to read the weight seen by each individual
load sensor allows use of this test to make cornering,
leveling and load sharing adjustments to the weighing
system.