6-3

give a combined fail result but not for the specific
load cell that failed. You will still have to determine
which Load Cell failed.

2.

Return to Zero Test (RTZ) - This test
returns a pass/fail result on whether
there is a zero load.

If you have an HI 215IT Junction
Box, individual load cells can be
tested.

If you do not have an HI 215IT
Junction box the result will be for
the combined load cells in your
weighing system.

3.

Digital Volt Meter (DVM) - This test
returns the voltage outputs from the
load cells.

If you have an HI 215IT Junction
Box, the voltage output for each
individual load cell is read.

If you do not have an HI 215IT
Junction box the voltage output
read will be for the combined
load cells in your weighing sys-
tem.

4.

System Test - Reads the weight for
the load cells in your system.

If you have an HI 215IT Junction
Box, the weight for each individ-
ual load cell can be read as well
as the internal reference.

If you do not have an HI 215IT
Junction box the weight read will
be combined weight for all the
load cells in your weighing sys-
tem.